15
CA 262/362/512 M262EN2
EVERY 50 HOURS OF OPERATION (Weekly)
Air cleaner
– Check/clean
Main filter – Cleaning with
compressed air
Fig. 13 Main filter
2
3
Fig. 12 Air cleaner
1. Locking braces
2. Cover
3. Main filter
4. Backup filter
5. Filter housing
Replace or clean the air cleaner’s main filter if
the warning lamp on the instrument panel lights
up when the diesel engine is operating at full
speed.
Undo the three locking braces (1). Then pull off the
cover (2) and pull out the main filter (3).
Do not remove the backup filter (4).
1
4
5
Replace the backup filter with a new one at every 5th
replacement or cleaning of the main filter. The backup
filter cannot be cleaned.
When replacing the backup filter (4), pull out the old fil-
ter from its holder, insert a new one and refit the air
cleaner in the reverse order to the instructions given in
the figure above.
Fig. 14 Air filter
4. Backup filter
Backup filter
– Replacement
4
If the main filter is to be cleaned, compressed air at
max. 5 bar (72 psi) pressure should be used. Blow up
and down along the paper creases on the inside of the
filter.
Hold the nozzle at least 2–3 cm (0.8-1.2 in) away from
the paper creases so that the paper does not tear un-
der the pressure of air.
Use protective goggles when working with
compressed air.
Wipe the inside of the cover (2) and filter housing (5).
Check that the hose clamps between the filter
housing and inlet hose are tightened and that
they do not leak. Check the entire length of the
hose all the way to the engine.
Once the main filter has been cleaned a maxi-
mum of 5 times, it must be replaced.
Summary of Contents for CA 262 Series
Page 2: ...19 ILF015WO1 ...