- Alarm output is a relay switching voltage to be load up to AC/DC24V/0.5A and when it is
activated by sensor, it is automatically switching on, can be released through the times or
by controller.
- Video output connector to be a BNC cable can be monitoring by means of directly
connection to monitor.
- Data can be process by RS485 or RS422 and when use many cameras, it can be used
by means of parallel connection. e.g. daisy chain configuration.
- Even if it must be used 2 twist paired cable in use of RS422, the terminal port which it
was connected with RS485 cable port with 1-paired cable when it is not necessary to
take a return data from camera.
Connect with two paired-cables (for (+) and (-) signal) from RS-485 terminals to terminal of
data box which is subsidiary of keyboard controller through hall of the back box. In wiring,
please keep to match to (+) pole and (-) pole.
Plug 8-pin cable from data box into keyboard controller. For use to data box, please use
the DC 12V / 1000mA of power supply at the same time it is a power source for a
keyboard controller.
Lastly, connect with 8-pin cable from data box to keyboard. It can be supplied power to
keyboard.
3.2.2 Connection diagrams
- Sensor can be connected max. 4-Channels and if it activates to detect by sensor with
PRESET
function, automatically the camera moves to the point by
PRESET MODE
.
NOTE: Power source must be used AC 24 V, 1.5 A output of electric current and use a
Double Winding Transformer as possible as.
Figure 7. CONNECTION DIAGRAM