6SHFLILFDWLRQV
8
6SHFLILFDWLRQV
(OHFWULFDO
Applicable to both channels. T
amb
= -25 to 50
E
C, V
BAT
= 24.0 V unless otherwise
specified.
Symbol
Parameter
Conditions
Min Nom Max Units
V
BAT
Battery Voltage
18.0 24.0 32.0
V
V
BSH
"Battery saver" high
threshold
Averaged. Battery
saver enabled
21.0
V
V
BSL
"Battery saver" low
threshold
Averaged. Battery
saver enabled
18.0
V
P
Q
Quiescent power
Relay de-energised
2.0
5.0
W
P
SBV
Standby power
PM "off"
15
30
mW
T
lim0
Thermal limit
I
MO
=0 @ T
lim0
70
E
C
I
DXBUS
DXBUS supply
current
Case temp. 20
E
C
12
A
30/HIWDQG5LJKW0RWRU2XWSXWV
Symbol Parameter
Conditions
Min Nom Max Units
f
PWM
PWM frequency
19.6
kHz
I
MO
Peak motor output
current
Duration 15 seconds.
Initial case
temperature 20
E
C.
Current limit
programmed to 60A
54.0 60.0 66.0
A
I
MO
15 minute continuous
motor current
T
amb
= 20°C
23.5
A
V
MO
Max. motor output
voltage
Full conduction, I
MO
= 10A
23.5
V