8
UVCS LED Light-Curing Conveyor Systems User Guide
Setup
Conveyor Setup
1.
Carefully remove all containers from the crate.
2.
Remove the conveyor system last to prevent damage to other contents.
3.
Remove the protective coverings from the conveyor. Place the conveyor on the conveyor rolling cart
or on a stable work surface.
4.
Unpack the BlueWave® AX-550 flood lamp system(s). Each flood lamp system is comprised of a
controller and emitter.
NOTE: It is recommended to assemble each flood lamp system and verify operation prior to
installation onto the conveyor cradle.
Mounting the Flood System(s)
Up to four BlueWave® AX-550 flood systems can be mounted onto your conveyor. The conveyor will be
configured for mounting of the emitter and controller pairs at the factory.
Installation requires the mounting of the emitter first to the cradle and securing with provided fasteners
and then the installation of the controllers onto the emitters with their supplied fasteners.
NOTE: Care must be taken when handling the emitters to protect the glass lens from damage or
contamination.
Preparation
Verify your UVCS conveyor is on a stable platform for all production purposes.
After you have installed your unit, raise the cradle by turning the locking handles and sliding the cradle up
the risers to a convenient working height (Figure 2).
Figure 2. Raise the Cradle to a Convenient Working Height