26
UVCS LED Light-Curing Conveyor Systems User Guide
Table 2. Troubleshooting
–
Conveyor Issues
Problem
Possible Cause
Corrective Action
Conveyor not operating
Main line circuit breaker
deployed
Toggle power switch off, then on, to reset the circuit
breaker. Check the amp rating of the breaker.
Compare it to specifications.
Improperly fastened connections
Check all connections. Verify that the power cord is
properly fastened.
Fuses for motor controller blown
Remove the fuses from the fuse holders (located in
the left side of control box) and check with an
ohmmeter, replace if defective.
Belt is hung up
Inspect the belt for any signs of a mechanical bind.
Tighten the belt if it is slipping on the drive roller.
Tension too low on belt (power
switch lights and motor turns
but belt does not move)
Use the tracking adjustment knobs to increase the
tension on the belt. Both knobs should be turned
the same amount to not affect the alignment.
Belt tracks to one side
Belt adjustment knobs are out of
position
Tighten the adjustment knob (located on the side to
which the belt is tracking towards) until the belt
tracks straight. Only minor adjustments should be
made at one time.
Spare Parts and Accessories
Options/Accessories
Item
Part Number
Personal Protection Equipment
Protective Goggles
—
Green
35286
Protective Goggles
—
Gray (standard model included with unit)
35285
Face Shield
35186
Radiometers
Dymax ACCU-
CAL™ 160 (LED)
41585
Conveyor
Exhaust Ducting plenum
43625
Conveyor Rolling Cart Kit
39215
Riser Kit, 2"
39218
Riser Kit, 6"
39280