29
Dymax BlueWave® LED Flood System User Guide
Specifications
Specifications
Property
Specification
Part Numbers
VisiCure®
405 nm
41260
Power cord NOT included*
41288
North American power cord with 120V plug
41291
Asian Power cord
PrimeCure™
385 nm
41261
Power cord NOT included*
41287
North American power cord with 120V plug
41290
Asian Power cord
RediCure™
365 nm
41262
Power cord NOT included*
41292
North American power cord with 120V plug
41289
Asian Power cord
Typical Initial Output
Intensities
VisiCure®: 950 mW/cm
2
PrimeCure™: 850
mW/cm
2
RediCure™: 500
mW/cm
2
Output Frequency
365 nm, 385 nm, or 405 nm
Power Requirements
100-240 V, 50-60 Hz (auto ranging)
Fuse
12 amp
LED Timer
0.1 to 9999.9 seconds
LED Activation
Foot switch, front panel, or PLC
Cooling
Forced air, filtered fan
Hour Meter
Unit operation and exposure (non-resettable)
Dimensions (W x D x H)
Power Supply : 13.00" x 18.25" x 4.50" [33.0 cm x 46.4 cm x 11.4 cm]
Array: 6.50" x 5.75" x 7.50" [ 16.5 cm x 14.6 cm x 19.1 cm]
Interconnect Cable Length
115" [292.1 cm]
I/O Port
25-Pin D-Sub
Weight
Power Supply: 15 lbs [6.8 kg]
Array: 8 lbs [3.6 kg]
Unit Warranty
1 year from purchase date
Operating Environment
20
–
35
C, non-condensing
Sound Level
68 decibels at 36" [91 cm] distance (at full power)
Certifications
RoHS, CE Marked
* For European customers, the appropriate power cord is added.
** When measured at 1 in [25 mm] distance with an ACCU-
CAL™ 50
-LED radiometer in flood mode