26
Dymax BlueWave® LED Flood System User Guide
Troubleshooting
The
BlueWave LED Flood System
constantly verifies the
performance of the power supply and LED head. If a problem
is detected, a diagnostic screen is displayed.
Please take note of the contents of the screen and contact
Dymax for support.
Figure 29. Diagnostics Screen
Table 2. Fault Symbols
Error
Screen
Name
Description
Array Thermal Cutoff
The array overheated. Verify the filter on the array is clean and replace if
necessary. Verify that the vents on the array are not blocked. Verify the array
is drawing room air which is less than 35 °C. Power down and restart the
controller to reset. If the problem persists, note the number following the
“E” and contact Dymax for further assistance
Controller Power
Supply Failure
There was a failure with the controller. Verify that the filters on the side of
the controller are not blocked. Clean the vents with a vacuum if necessary.
Do not attempt to open the controller. Power down and restart the
controller to reset. If the problem persists, note the number following the
“E” and contact Dymax for further assistance
Array Not Connected,
Array Malfunction, or
Cable Problem
There was a problem with the connection between the array and the
controller or LEDs which have failed.
Turn off the controller and very that the cable is firmly attached by screws on
the controller and the array.
Power down and restart the controller to reset. If the problem persists, note
the number following the “E” and contact Dymax for fu
rther assistance
Controller Board
Failure
There was a failure with the controller board. Power down and restart the
controller to reset. If the problem persists, note the number following the
“E” and contact Dymax for further assistance
Flashing Power
Supply Thermal
Warning
Indicates that the power supply has exceeded the recommended
temperature limit. Check the filters on the controller for any clogs and if
necessary, clean the filters. Verify that ambient temperature around the
controller is below 35 °C. The unit will continue to operate normally unless
the temperature in the controller continues to rise.
Flashing Array
Thermal Warning
Indicates that the cooling air drawn into the array is has exceeded the
recommended temperature limit of 35 °C. Check the filter on the array for
any clogs and if necessary, clean or replace the filter. Operate the unit in an
ambient temperature of 35 °C or less. Verify that hot air from other
equipment is not being drawn into the array. The unit will continue to
operate unless the cooling air temperature continues to rise.