25
RMO100A Accessories, Contact Information
9 Technical Data
9.1 Mains Power Supply
- Connection
according to IEC/EN60320-1; UL498, CSA 22.2
- Voltage single phase
110 V - 230 V AC
- Frequency
50 / 60 Hz
- Fuse
15 A / 250V, type F
9.2 Output data
- Test current
5 A
– 100 A DC
- Tipycal Accuracy
± 0,25 % rdg ± 0,25 % FS
9.3 Environmental conditions
- Indoor use
- Altitude below 2000 m
- Temperature -10 °C - +55 °C / 14 °F - +131 °F
- Maximum relative humidity 95 % for temperatures up to 31 °C, decreasing linearly to 40 %
relative humidity at 55 °C
- Mains supply voltage fluctuations up to ±10 % of the nominal voltage
- Installation/overvoltage category II
- Pollution degree 2
9.4 Mechanical protection
- IP43
9.5 Dimensions and Weight
- Dimensions
198 x 255 x 380 mm (W x H x D) without handle
7,8 x 10 x 15 in
- Weight
7 kg / 15,4 lbs
9.6 Safety Standards
- European standards
EN 61010-1
LVD 73/23/EEC
- International standards
IEC 61010-1
UL 3111-1
CAN/CSA-C22.2 No 1010.1-92
9.7 Electromagnetic Compatibility (EMC)
CE conformity
EMC standard 89/336/EEC
Emission
EN 50081-2, EN 61000-3-2/3
Interference Immunity
EN 50082-2
9.8 USB Interface
RMO100A is equipped with an USB serial interface to connect to an external computer.