Usage
12 Operation
Prior to working on the unit or in case of
danger, disconnect it from the mains.
12.1 Operating panel
1 2 3 4
5
6
1
Fault button with orange LED
2
Filter change button with orange LED
3
Service key with blue LED
4
Standby button with blue LED
5
Pressure range display/adjustment
6
Pressure dew point display
Different messages and the status of the unit are
displayed on the operating panel. In addition, dif-
ferent functions can be started via the buttons.
The device is operated via the operating panel of
the main control. The auxiliary control is inactive
(standby button flashing) and cannot be oper-
ated.
Buttons
Fault button
Display of alarm messages
with different levels of
importance. This can be
faults, warning messages
and information (see "12.7
Fault""12.8 Emergency
mode").
Filter replacement
button
"Maintenance required" dis-
play for the various filters
(see "13.2 Changing the fil-
ter").
Service key
Check of the safety valve
and adjustment of the pres-
sure range (see "9.2
Checking the safety valve"
and "10.1 Adjustment of
the switch-on/cut off pres-
sure").
Standby button
Switching between normal
operation and standby
mode (see"12.3 Normal
operation") and "12.4
Standby mode").
Pressure range
The pressure is displayed and can be adjusted in
this area.
The pressure is displayed via:
1. Blue LED (
£
4.5 bar):
only illuminates while the pressure is building up
during start-up operation
2. - 10. Blue LEDs (= 5 - 9 bar):
these indicate the pressure status in increments
of 0.5 bar
11. Orange LED (> 9 bar):
the pressure in the container is too high (i.e. out-
side the adjustment range).
Adjustment options (see "10.1 Adjustment of the
switch-on/cut off pressure").
Pressure dew point
The current pressure dew point temperature is
displayed in this area. The compressed air can
cool down to this temperature without the water
condensing.
The pressure dew point is displayed via:
4 blue LEDs: 0°C / 5°C / 10°C / 15°C
1-2 blue LEDs light up when the system is run-
ning in the normal working range.
1 orange LED:
³
20°C, i.e. dry compressed air is
no longer ensured.
As soon as the orange LED lights up the blue
LEDs go out.
Usage
28
9000-610-72/30 1907V007