WARNING
: Failure to properly ground the generator can result in electrocution.
25
Attach grounding wire
a.
Ground the generator by tightening the grounding
nut against a grounding wire.
b.
Connect the other end to a copper or brass
grounding rod that’s driven into the earth.
A generally acceptable grounding wire is a No. 12 AWG
(American Wire Gauge) stranded copper wire.
Grounding codes can vary by location. Please contact a local
electrician to check the grounding regulations for your area.
Step 6 - Grounding the Generator
High Altitude Operation
At high altitudes, the standard carburetor air/fuel mixture will be too rich. The performance will decrease,
and fuel consumption will increase. A very rich mixture will also foul the spark plug and cause hard starting.
Operation at an altitude that differs from that at which this engine was certified, for extended periods of
time, may increase emissions. High altitude performance can be improved by specific modifications to the
carburetor. If you always operate your generator at altitudes above 3,000 feet (900 meters), have a dealer
perform this carburetor modification. This engine, when operated at high altitude with the carburetor
modifications for high altitude use, will meet each emission standard throughout its useful life. Even with
carburetor modification, engine horsepower will decrease by about 3.5% for each 1,000-foot (300-meter)
increase in altitude. The effect of altitude on horsepower will be greater than this if no carburetor
modification is made.
When the carburetor has been modified for high altitude operation, the air/fuel mixture will be too lean
for low altitude use. Operation at altitudes below 3,000 feet (900 meters) with a modified carburetor may
cause the engine to overheat and result in serious engine damage.
Summary of Contents for DUAL FUEL XP12000DX
Page 2: ......
Page 5: ......
Page 26: ...26 ...
Page 35: ...35 ...
Page 38: ...38 ...
Page 45: ...45 Hours Total The number of hours the generator has been run in total 4 ...
Page 46: ...46 ...
Page 49: ...MAINTENANCE LOG Date Generator Hours Maintenance Performed 49 ...
Page 68: ...WIRING DIAGRAM 68 ...
Page 69: ...69 ...
Page 75: ......
Page 76: ...5800 Ontario Mills Parkway Ontario CA 91764 United States 844 DUROMAX REV XP12000DX 09102021 ...