Maintenance
Operating Instructions 755 B, 756 B/F - 00.0 - 02/2021
295
3. Next, select
Knife change position
.
The knives (2) extend with a clicking sound and can be seen at
the piping strip rest table (1).
Fig. 244: Replacing the incision knives for piping ends (1)
Fig. 245: Replacing the incision knives for piping ends (2)
4. Loosen the screw (4) by a 1/4 turn while holding in place and removing
the knife (2) with a pair of tweezers (3).
(1)
- Piping strip rest table
(2)
- Knife
(2) - Knife
(3)
- Tweezers
(4)
- Screw (covered)
①
②
④
③
②