Adjusting and testing hook thread monitor
The display switches to
Test bobbin thread monitor
.
Information
When the light barriers are correctly aligned, a reflection occurs when an
empty bobbin is turned.
The intensity of the reflection is illustrated by a black bar and a number
between
1
and
15
.
If the value is above the minimum value of
8
, the display shows an arrow
between reflecting head and hook thread bobbin. A signal tone will sound
at the same time.
Important
If the light barrier setting is correct, the maximum value of
15
must be
reached when the infrared beam hits the area of the reflecting surface of
the bobbin.
The black bar is within the green range.
Fig. 165: Adjusting and testing hook thread monitor
To adjust the hook thread monitor:
1. Press the desired button.
Symbols
Meaning
Adjust sensitivity left
• 0 - 15
Adjust sensitivity right
• 0 - 15
Summary of Contents for 755 B
Page 1: ...755 B 756 B F Operating Instructions...
Page 6: ...Table of Contents 4 Operating Instructions 755 B 756 B F 00 0 02 2021...
Page 10: ...About these instructions 8 Operating Instructions 755 B 756 B F 00 0 02 2021...
Page 18: ...Machine description 16 Operating Instructions 755 B 756 B F 00 0 02 2021...
Page 292: ...Programming 290 Operating Instructions 755 B 756 B F 00 0 02 2021...
Page 306: ...Maintenance 304 Operating Instructions 755 B 756 B F 00 0 02 2021...
Page 328: ...Setup 326 Operating Instructions 755 B 756 B F 00 0 02 2021...
Page 330: ...Decommissioning 328 Operating Instructions 755 B 756 B F 00 0 02 2021...
Page 332: ...Disposal 330 Operating Instructions 755 B 756 B F 00 0 02 2021...
Page 354: ...Technical data 352 Operating Instructions 755 B 756 B F 00 0 02 2021...
Page 373: ......