Maintenance
Service Instructions 2112-5 - 00.0 - 02/2020
79
9.3.2 Draining the water-oil mixture
The collection tray (2) of the pressure regulator will show accumulation of
a water-oil mixture.
Proper setting
The water-oil mixture must not rise up to the level of the filter element (1).
Check the level of the water-oil mixture in the collection tray (2).
Fig. 38: Draining the water-oil mixture
To drain the water-oil mixture:
1. Disconnect the machine from the compressed air supply.
2. Place the vessel under the drain screw (3).
3. Loosen the drain screw (3) completely.
4. Allow the water-oil mixture to drain into the vessel.
5. Tighten the drain screw (3).
6. Connect the machine to the compressed air supply.
NOTICE
Property damage from excess liquid!
Too much liquid can result in damage to the machine.
Drain liquid as required.
(1)
- Filter element
(2)
- Collection tray
(3)
- Drain screw
①
②
③
Summary of Contents for beisler 2112-5
Page 1: ...Service Instructions...
Page 8: ...About these instructions 6 Service Instructions 2112 5 00 0 02 2020...
Page 40: ...Setting up the machine 38 Service Instructions 2112 5 00 0 02 2020...
Page 76: ...Programming 74 Service Instructions 2112 5 00 0 02 2020...
Page 84: ...Maintenance 82 Service Instructions 2112 5 00 0 02 2020...
Page 86: ...Decommissioning 84 Service Instructions 2112 5 00 0 02 2020...
Page 88: ...Disposal 86 Service Instructions 2112 5 00 0 02 2020...
Page 96: ...Technical data 94 Service Instructions 2112 5 00 0 02 2020...
Page 103: ......