Machine head
Service Instructions 745-35-10 D - 00.0 - 10/2017
29
3.8.2 Removing a needle bar from the needle bar linkage
Fig. 19: Removing a needle bar from the needle bar linkage (1)
To remove a needle bar from the needle bar linkage:
1.
Loosen the clamping screw (1).
2.
Pull out the bearing bolt (3).
3.
Pull the support plate (2) off the needle bar linkage.
(1)
- Clamping screw
(2)
- Support plate
(3)
- Bearing bolt