Programming
252
Service Instructions 745-35-10 D - 00.0 - 10/2017
Multi test I/O
The display switches to
Multi test I/O
.
Fig. 216: Multi test I/O
To carry out an input and output test:
1.
Select an input in the left area:
Inputs 745-35-10 D
(1)
- Input
(2)
- Increase selection by 1
(3)
- Display of the selected input
(4)
- Reduce selection by 1
(5)
- Clear selection
(6)
- Manual test On/Off
(7)
- Automatic test On/Off
(8)
- Output
①
②
③
④
⑤
⑧
②
③
④
⑤
⑦
⑥
S1
Needle thread monitor left
S2
Needle thread monitor right
S3
Folder down
S4
Folding station swiveled in
S5
Corner knife swiveled in
S6
Sewing material removed/cover monitor
S7
Pedal left, forward
S8
Pedal left, backward
S9
Pedal right, forward
S10
Pedal right, backward
S11
Clamp adjustment right
S12
Clamp adjustment left
Summary of Contents for 745-35-10 D
Page 1: ...745 35 10 D Service Instructions...
Page 6: ...Table of Contents 4 Service Instructions 745 35 10 D 00 0 10 2017...
Page 10: ...About these instructions 8 Service Instructions 745 35 10 D 00 0 10 2017...
Page 74: ...Machine head 72 Service Instructions 745 35 10 D 00 0 10 2017...
Page 84: ...Transport carriage 82 Service Instructions 745 35 10 D 00 0 10 2017...
Page 116: ...Light barriers 114 Service Instructions 745 35 10 D 00 0 10 2017...
Page 122: ...Aligning the machine head 120 Service Instructions 745 35 10 D 00 0 10 2017...
Page 128: ...Folder 126 Service Instructions 745 35 10 D 00 0 10 2017...
Page 146: ...Throw over stacker 144 Service Instructions 745 35 10 D 00 0 10 2017...
Page 282: ...Programming 280 Service Instructions 745 35 10 D 00 0 10 2017...
Page 292: ...Maintenance 290 Service Instructions 745 35 10 D 00 0 10 2017...
Page 294: ...Decommissioning 292 Service Instructions 745 35 10 D 00 0 10 2017...
Page 296: ...Disposal 294 Service Instructions 745 35 10 D 00 0 10 2017...
Page 308: ...Troubleshooting 306 Service Instructions 745 35 10 D 00 0 10 2017...
Page 337: ......