Adjusting the hook and needle bar
26
Service Instructions 512-211-01/532-211-01 - 00.0 - 06/2016
Cover
• Open the hook flap (
Fig. 18: Adjusting the loop stroke and needle guard
Adjusting steps
1.
Use the handwheel to adjust the needle bar so that the corresponding
marker line (6/7) is aligned with the needle bar bush.
2.
Loosen the screw (4).
3.
Remove the cover ring. When doing this make sure that the hook (2)
does not work loose and fall.
4.
Twist the driver (3) accordingly.
5.
Shift the driver (3) axially so that the needle (5) rests against the driver
tip and is easily pushed aside.
6.
Insert the cover ring.
7.
Tighten the screw (4).
(1)
- Hook tip
(2)
- Hook
(3)
- Driver
(4)
- Screw
(5)
- Needle
(6)
- Marker line for class 512
(7)
- Marker line for class 532
512
532
①
⑤
②
③
④
⑥
⑦
Summary of Contents for 512-211-01
Page 6: ...Table of Contents 4 Service Instructions 512 211 01 532 211 01 00 0 06 2016...
Page 22: ...Work principles 20 Service Instructions 512 211 01 532 211 01 00 0 06 2016...
Page 72: ...Maintenance 70 Service Instructions 512 211 01 532 211 01 00 0 06 2016...
Page 76: ...Appendix 74 Service Instructions 512 211 01 532 211 01 00 0 06 2016 Circuit diagram Sheet 2...
Page 77: ...Appendix Service Instructions 512 211 01 532 211 01 00 0 06 2016 75 Circuit diagram Sheet 3...
Page 78: ...Appendix 76 Service Instructions 512 211 01 532 211 01 00 0 06 2016 Circuit diagram Sheet 4...
Page 79: ...Appendix Service Instructions 512 211 01 532 211 01 00 0 06 2016 77 Circuit diagram Sheet 5...
Page 80: ...Appendix 78 Service Instructions 512 211 01 532 211 01 00 0 06 2016...
Page 81: ......