![DURAVANT QC CONVEYORS PF52 Maintenance Manual Download Page 5](http://html1.mh-extra.com/html/duravant/qc-conveyors-pf52/qc-conveyors-pf52_maintenance-manual_2541747005.webp)
PF Conveyors | Installation, Operation & Maintenance Manual
5
Conveyor Installation
/ Ugradnja pokrete trake
Lock-out power. Emergency stops are required and must be installed as part of the tables. The circuitry for the emergency stop is integrated into the conveyor’s
control panel. In addition, the installer must provide a lockable means of power isolation.
Isključite napajanje. E-blokatori su obavezni i moraju se ugraditi kao dijelovi stolova. Sklop za E-stop integriran je u kućište upravljača transportne trake. Dodatno, instalater
mora osigurati sredstvo za izolaciju struje koje se može zaključati.
u
Install Conveyors In Tables
/ Ugradnja transportnih traka u stolovima
EN
1
Separate the tables so the
service cavity within the ECU
table is accessible.
2
Slide the ECU conveyor, tail
first, into the ECU table.
3
Move the tables back to-
gether to allow access to the
PREP tables service cavity.
4
Slide the PREP conveyor, tail
first, into the PREP table.
CR Odvojene stolice tako da je servisna
šupljina u ECU stolu dostupna
Gurnite ECU transporter, počevši sa
repom, u ECU stol
Pomaknite stolove natrag zajedno
kako biste omogućili pristup priprem-
noj šupljini
Gurnite transportnu traku stola
za pripremu, počevši sa repom, u
pripremni stol
u
Check Conveyor Elevations
/
Provjerite visine transportera
3-5mm
25mm
OAT
3-5mm
3-5mm
EN
1
Confirm the discharge end of
the ECU table conveyor is 3-5
mm above the OAT surface.
WARNING
WARNING
Leave a 25 mm gap between the
conveyor and the OAT; a smaller
gap creates a pinch hazard.
2
Confirm that the conveyors
transition point, at the end of
the PREP table, is 3-5 mm above
the ECU table. The conveyor bear-
ing housings should be between
0-5 mm apart at transition.
3
Confirm that the top of the
PREP tables’ conveyor belt
is 3-5 mm below the bottom of
the chute.
WARNING
WARNING
The chute and conveyor create
a pinch point; proper guarding
must be installed.
4
Make adjustments as needed.
The mounting height can be
adjusted by loosening the hex head
screws with a 10 mm wrench.
CR Potvrdite da je kraj pražnjenja stolne
transportne trake ECU 3-5 mm iznad
površine OAT-a
UPOZORENJE
Ostavite razmak od 25 mm
između transportne trake i OAT-a;
manji razmak stvara opasnost od
uklještenja
Potvrdite da su transportne trake
na prijelaznom kraju transportne
trake za pripremni stol 3-5 mm iznad
ECU transportera; Kućišta ležajeva
transportera trebaju biti međusobno
udaljena između 0-5 mm pri prijelazu
Provjerite je li gornji dio transportne
trake PREP stolova 3-5 mm ispod
dna žlijeba.
UPOZORENJE
Žljeb i transporter stvaraju točku
stezanja; mora se postaviti
odgovarajuća zaštita.
Po potrebi izvršite prilagodbe.
Visina montaže može se podesiti
otpuštanjem šesterokutnih vijaka
ključem od 10 mm.