LED diode upravljača
WARNING: Due to the risk of electric shock, maintenance of the control panel should be performed ONLY by service technician’s or licensed electrician’s.
UPOZORENJE: Zbog opasnosti od strujnog udara, održavanje unutarnje upravljačke ploče treba obavljati SAMO serviser ili licencirani električar.
12V
24V
12V
12V
24V
12V
12V
24V
12V
12V
24V
12V
EN
The conveyor is ready to start.
The emergency stop is activated.
Reset the emergency stop.
The clear plastic guards on the
ECU table are not making contact
with the sensors. Check the clear
plastic guards.
The clear plastic guards on
the PREP table are not making
contact with the sensors. Check
the clear plastic guards.
CR Pokretna traka je spremna za rad
Hitno zaustavljanje je aktivirano.
Resetirajte tipku za hitno zaustav-
ljanje.
Zaštita na ECU transporteru ne
Dolazi u dodir sa senzorima.
Provjerite štitnike
Zaštita na transportnim trakama stola
za pripremu ne ostvaruje kontakt sa
senzorima. Provjerite štitnike
12V
24V
12V
12V
24V
12V
EN
A line in the power is deactivated.
The circuit breaker may have
tripped and needs to be reset.
The power supply LED is red.
There is a faulty condition and the
cables inside of the control panel
must be checked.
CR Linija napajanja deaktivirana.
Prekidač se možda aktivirao i treba
ga resetirati
LED lampica za napajanje je
crvena. Postoji kvar i potrebno je
provjeriti žice unutar ploče