38
Stop! Read Safety information above.
1.
Set thermostat to lowest setting.
2.
Turn off all electric power to the appliance.
3.
This appliance is equipped with an ignition device which
automatically lights the burner. DO NOT try to light the
burner by hand.
4.
Remove the front jacket panel.
5.
Turn the gas control knob clockwise
to “OFF”.
6.
Wait
fi
ve (5) minutes to clear out any gas. Then smell
for gas, including near the
fl
oor. If you smell gas,
STOP! Follow “B” in the safety information above on
this label. If you don’t smell gas go on to next step.
7.
Turn the gas control knob counterclockwise
to
“ON”.
8.
Replace front jacket panel.
9.
Turn on all electrical power to the appliance.
10.
Set the thermostat to desired setting.
11.
If the appliance will not operate, follow the instructions
“To Turn Off Gas To Appliance” and call your service
technician or gas supplier.
To Turn Off Gas To Appliance
1.
Set the thermostat to lowest setting.
2.
Turn off all electric power to the appliance if service is
to be preformed.
3.
Remove the front jacket panel.
4.
Turn gas control knob clockwise
to “OFF”.
5.
Replace the front jacket panel.
OPERATING INSTRUCTIONS
WARNING
If you do not follow these instructions
exactly, a fi re or explosion may result causing
property damage, personal injury or loss of
life.
• This appliance is equipped with an ignition device
which automatically lights burner.
Do NOT try to
light this burner by hand.
• Before operating smell all around appliance area
for gas. Be sure to smell next to
fl
oor because
some gas is heavier than air and will settle to the
fl
oor.
• Use only your hand to turn the gas shutoff
valve
. Never use tools. If valve will not turn
by hand, do not try to repair it, call a quali
fi
ed
service technician. Force or attempted repair may
result in
fi
re or explosion.
• Do not use this appliance if any part has
been under water.
Immediately call a quali
fi
ed
service technician to inspect appliance and to
replace any part of control system and any gas
control which has been under water.
!
OFF
ON
INLET
GAS CONTROL KNOB
SHOWN IN "ON" POSITION
Figure 24 - Gas Valve
CAUTION
WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use
any phone in your building.
• Immediately call your gas supplier from a
neighbor’s phone. Follow the gas supplier’s
instructions.
• If you cannot reach your gas supplier, call the
fi
re
department.
!
!
Summary of Contents for Q90-100
Page 2: ...2 DIMENSIONS 2 Figure 1 Boiler Dimensions...
Page 12: ...12 NEAR BOILER PIPING Figure 2 Single Zone Boiler Piping...
Page 14: ...14 Figure 4 Two Zone Boiler Piping With Circulators NEAR BOILER PIPING...
Page 19: ...19 Figure 9 Diaphragm Type Expansion Tank Piping NEAR BOILER PIPING...
Page 20: ...20 Figure 10 Conventional Closed Type Expansion Tank Piping NEAR BOILER PIPING...
Page 24: ...24 Figure 12 Roof Vent Intake Terminations COMBUSTION AIR AND VENT PIPE VENT AIR INTAKE...
Page 32: ...32 Figure 21 Ladder Wiring Diagram ELECTRICAL WIRING...
Page 34: ...34 Figure 23 Ladder Diagram for Figure 22 ELECTRICAL WIRING...
Page 40: ...40 S9381A INTEGRATED BOILER CONTROL OPERATION AND ADJUSTMENTS Table 9 State Code Definitions...
Page 41: ...41 S9381A INTEGRATED BOILER CONTROL OPERATION AND ADJUSTMENTS Figure 26 Sequence of Operation...
Page 48: ...48 TROUBLESHOOTING Table 10 Error Codes...
Page 55: ...NOTES...
Page 56: ...DUNKIRK BOILERS 2201 Dwyer Avenue Utica NY 13501 web site www ecrinternational com...