Calibration via PRIMING SWITCH (continued)
3
The appropriate metering unit will run until the PRIMING
SWITCH is pressed again. Product is collected in this
time. The operator is in control of the amount of product
metered out so is able to stop the metering unit when
the collecting container is at a suitable fill level.
4
Weigh the contents of the container. Write down the
amount exactly as displayed. Do not round up or round
down the value measured.
Scales must be accurate to
2 grams.
5
Enter the recorded value into the ProSeries head unit as
shown. Press ‘ENTER’ to confirm as requested.
Always use consistant units of measure ie grams or
Kilograms.
6
Press ‘ENTER’ again. The instrument will then calculate
the settings in order to correctly deliver the product. The
‘error’ value is only the difference between the new and
old settings. Subsequent recalibrations with the same
product will only report small differences.
7
Press ‘ENTER’ again to confirm and store the new
settings.
8
Repeat the calibration process. In this case, the ‘Error’
reported will be very small if any. Remember to press
the ‘ENTER’ key to accept the settings.
This repeat
calibration is especially important if the metering units
have been adjusted from very different values since the
last time the machine was used.
9
NOTE: If, when presing the priming switch the motors
do not turn but there are no other errors, it could be
that the previous calibration was wrongly entered. The
metering speed is out of the range of the motor speed.
This can be corrected by manually entering a ‘calibration
factor’ as follows:
(i) Press the ‘SETUP’ menu key.
(ii) Press the key below the wrench icon.
(iii) Use the up down left right arrows to select the
product. The left right arrows will appear when the
cursor is moved up one line from the ‘Cal Fact’.
(iv) Move the arrow to the ‘Cal Fact’ line, type 0.500
and hit the ‘ENTER’ key. (You need to enter the leading
zero as the machine will not accept the ‘.’ as a first
character.)
(v) Hit the ‘ESC’ key to return to the ‘SETUP’ menu or
hit the ‘MAIN’ key to return to the ‘MAIN’ menu.
(vi) Repeat the calibration process from step 1.
‘Enviro DD55’
Calibration
Summary of Contents for Enviro DD55
Page 2: ......
Page 6: ...4 Enviro DD55 Dimensions Capacities 1 7 ...
Page 16: ...14 ...
Page 20: ...18 ...
Page 24: ...22 ...
Page 30: ...28 ...
Page 31: ...29 Pt No 67441 Issue 0918 Enviro DD55 Calibration Notes ...
Page 43: ...41 Pt No 67441 Issue 0918 Enviro DD55 Notes ...
Page 44: ...42 3 1 3 2 3 1 3 1 3 2 3 2 3 1 3 4 1 7 9 1 3 2 3 2 2 6 5 2 7 4 3 2 3 2 3 2 3 2 3 2 3 8 3 2 ...
Page 46: ...44 12 14 13 10 2 9 11 7 8 1 3 4 5 6 16 15 Enviro DD55 Disc Assemblies or 17 ...
Page 50: ...48 Enviro DD55 Disc Assemblies 1 2 3 4 5 6 7 8 ...
Page 54: ...52 Enviro DD55 Bushes Mainframe Wheels 5 6 7 8 2 3 4 9 10 1 6 7 8 4 5 ...
Page 56: ...54 Enviro DD55 Bushes Wing Wheels 3 10 9 1 11 2 5 4 8 7 6 4 8 7 6 12 6 8 7 ...
Page 58: ...56 Enviro DD55 Bushes Wing Pivot 1 2 3 1 4 5 6 7 ...