Maintenance Schedule
(
Refer also to Summary Chart, above)
1
Bolted Connections
All bolted connections of the machine should be
checked after the first 3 to 5 hours of operation and
retightened if necessary and thereafter at regular
intervals. It is suggested that this is done every 500
hectares or annually, whichever occurs first.
2
Pivot Pins & Ram Clevis
Pivots must be greased regularly (weekly or after every
75Ha) to provide lubrication and flush out any dirt.
3 Framework
The framework structure should be inspected annually
for defects, i.e., cracks in members or welded
connections. The framework should be cleaned prior to
the inspection.
4 Metering Units
Ensure that the metering units are clean and that the
rubber sealing lip is not damaged. The sealing lip
is located along the base of the trap door hinge. A
damaged sealing lip can cause seed delivery problems.
Maintenance & Care - Schedule
‘Enviro DD55’
Maintenance & Care
Components
Daily
Weekly
Pre Season
(or after 20Ha)
(or after 75Ha)
(or 500 Ha)
Depth Adjustment Collar
●
●
●
Wheel Nuts
●
●
●
Pivot Pin Fasteners
●
●
Coupling & Safety Chains
●
●
Roller Chains
●
●
Hydraulics (Oil Leaks)
●
●
Tyre Pressures (58psi /4.0 bar)
●
●
Bolted Connections
●
Summary of Contents for Enviro DD55
Page 2: ......
Page 6: ...4 Enviro DD55 Dimensions Capacities 1 7 ...
Page 16: ...14 ...
Page 20: ...18 ...
Page 24: ...22 ...
Page 30: ...28 ...
Page 31: ...29 Pt No 67441 Issue 0918 Enviro DD55 Calibration Notes ...
Page 43: ...41 Pt No 67441 Issue 0918 Enviro DD55 Notes ...
Page 44: ...42 3 1 3 2 3 1 3 1 3 2 3 2 3 1 3 4 1 7 9 1 3 2 3 2 2 6 5 2 7 4 3 2 3 2 3 2 3 2 3 2 3 8 3 2 ...
Page 46: ...44 12 14 13 10 2 9 11 7 8 1 3 4 5 6 16 15 Enviro DD55 Disc Assemblies or 17 ...
Page 50: ...48 Enviro DD55 Disc Assemblies 1 2 3 4 5 6 7 8 ...
Page 54: ...52 Enviro DD55 Bushes Mainframe Wheels 5 6 7 8 2 3 4 9 10 1 6 7 8 4 5 ...
Page 56: ...54 Enviro DD55 Bushes Wing Wheels 3 10 9 1 11 2 5 4 8 7 6 4 8 7 6 12 6 8 7 ...
Page 58: ...56 Enviro DD55 Bushes Wing Pivot 1 2 3 1 4 5 6 7 ...