Slope/Demand Slope: ...... Utilizes a function within the system to watch the
temperature change as the unit freezes a barrel. If utilizing
the slope feature and the unit sees a lack of temperature
change during freeze down, the unit will cycle off. This
will prevent a freeze up condition due to a long run time.
Demand Slope range: 0 to -0.2
Temp. Comp.: ................... Temperature compensation, utilized when the slope feature
is turned on. It prevents the system from seeing the
slope temperature curve until a determined temperature
is reached. Once that temperature has been reached
then the system will examine the curve and shut down if
necessary. Temp. Comp. Range: -10
to 22°F
Temperature Offset: .......... A function that allows temperature adjustment to the
operator. Adjustable from 1-9 and 5 being neutral/no
change, Lower than 5= colder and greater than 5=warmer
Transducer: ...................... An electronic control used to measure the cylinder
pressure for mix pump operation.
U.I./ User Interface: .......... The board that lies directly behind the membrane switch
on the front panel. This board houses the LED screen that
displays the menus and operations. The membrane switch
is connected to this board via a ribbon cable. This board
also has its own software.