background image

 

10

 

     

FAULT FINDING 

 

DOOR WILL NOT OPERATE FROM 

 

A)

 

Control Box 

 

   Check power is on to Control Unit (Red L.E.D. illuminated). 

 

   IF NOT, check mains plug and fuse. 

 

   Plug fully engaged on top of Control Box. 

 

   Motor wiring connections properly engaged. 

 

   Manual release lever in “engaged” position. 

 

   Limit Switch cams correctly set i.e. upper Limit Switch for fully open position,  

                     lower limit switch for fully closed position. 

 

   Move door manually to half-closed position and try again. 

 

   Try operation with Hand Transmitter. 

 

B)

 

Handheld Transmitter 

 

Check door operates correctly using the Push Button on Power Head to prove system is OK. 

 

Try recoding Transmitter. 

 

Check battery in Transmitter is correctly fitted.  L.E.D. should illuminate.   

 

Try new battery. 

 

Move aerial manually and try in different orientations, keeping it away from steel  
  structures and electrical cables. 

 

DOOR OPERATES BUT FAILS TO FULLY OPEN OR REVERSES BEFORE CLOSING. 

 

   Check manual operation for correct balance, not binding.  Adjust if necessary. 

 

Spray silicone lubricant into tracks, 

do not grease

 

Check/adjust safety sensitivity setting. 

 

Check Limits. 

 

BANGS HARD ON TRACK STOPS WHEN FULLY OPEN 

 

Check top (Cam “T”) Limit Switch setting. 

 

Adjust if necessary. 

 

BANGS HARD ON GROUND AND REVERSES WHEN FULLY SHUT 

 

Check bottom (Cam “B”) Limit Switch setting. 

 

Adjust if necessary. 

 

DOOR FAILS TO TRAVEL DOWN FROM OPEN POSITION – MOTOR RUNS AND 
ROLLER DOOR BALOONS 

 

Check door curtain has smooth line of entry into tracks, as near vertical as possible. 

 

Check door tension is not too great, reduce spring tension if necessary.  If the above  

 

does not cure the problem, then the door may require a weight bar to be fitted. 

 

SHORT RANGE REMOTE CONTROL 

 

Remote Control should give minimum of 6m range. 

 

Check battery is correctly fitted in Transmitter. 

 

Try new battery. 

 

Move aerial and try in different orientations, keeping away from steel structures and 
electrical cables. 

 

DOOR OPERATES BUT FAILS TO FULLY OPEN BUT REVERSES TO CLOSED 
POSITION. 

 

Change Dip switch 2 on. 

 

Reset Limits. 

 

Re-adjust Sensitivity Adjustment. 

Summary of Contents for Dts-12

Page 1: ...INSTALLATION MANUAL Comply to SANS IEC 60 335 2 103 NRCS Cert no 88934 002 DTS SECURITY PRODUCTS CC P O BOX 3399 EDENVALE 1610 TELEPHONE 086 1000 387 Spartan 2711 392 5540 H O Pretoria 2712 361 5528 A...

Page 2: ...ectronic obstruction system that provides safe and reliable operation It is however a legal requirement in some countries to also install a Photo electric sensor across the door way Please check this...

Page 3: ...commended side clearance between door curtain and the inside edge of mounting bracket is 110mm The recommended side clearance between door curtain and the outside edge of mounting bracket is 160mm If...

Page 4: ...nd others where the drum wheel door is less than 135mm from the centre shaft support bracket 1 Release the engage disengage lever on the motor so that it runs free 2 Make sure that there is enough spa...

Page 5: ...ation shown inside looking out Lift door onto mounting brackets ensuring curtain roll is correct way round centralize curtain roll with opening Refer to door installation instructions New installation...

Page 6: ...t cam T controls open position of door Bottom limit cam B controls closed position of door STEP 3 Slightly loosen the three retaining screws so that the cams can be easily moved See Figure 7 Figure 7...

Page 7: ...rol Box Front and check closing and stopping position Figure 9 i Door fully closed ii Door slightly closed STEP 12 If you are achieving the desired stop position then replace the Limit Switch Cover Pl...

Page 8: ...ot UP for open traveling sensitivity clockwise is for more force and anti clockwise for less force Whilst the door is traveling turn the obstruction sensitivity pot slowly until an overload condition...

Page 9: ...opened manually Obstruction Detection During an open cycle if an obstruction is detected the door will stop During a closing cycle if an obstruction is detected the door will reverse to the open posi...

Page 10: ...heck manual operation for correct balance not binding Adjust if necessary Spray silicone lubricant into tracks do not grease Check adjust safety sensitivity setting Check Limits BANGS HARD ON TRACK ST...

Page 11: ...SPEC Motor Type Permanent Magnet D C Motor Voltage 24V DC CONTROL BOARD SPEC Control Board Voltage 24V DC 5V DC Light Glove Voltage 36V 1 5W Receiver specification Receiver type FSK AM Built in RF Fr...

Page 12: ...ion In the event of the goods being supplied by dealer merchant agent or duly appointed installer of DTS Security Products the claim must be directed to that supplier The carriage of goods is for the...

Reviews: