8
Control box set up
Remove cover on front of control box
1.
Wiring diagram
J1, J2
(AC24V)
: Transformer output
J3
A, A+, I, OV, +24 : Manual push button / Receiver Input NO / Infra red beam
/Common & DC auxiliary voltage.
J7
SP+, SP-
: Battery Backup Connector
J8 M1, M2, OP, COM, CL : Motor & Limit wires
LAMP
: 36V 1.5W light socket
2.
Auto close option
Dipswitch 1 OFF-E (Enable) position: auto close feature is on –
Infra red beam must be fitted.
Dipswitch 1 ON-D (Disable) position: auto close feature is off.
3. Right hand and left hand installation.
Dipswitch 2 on “R” position is for right hand installation.
Dipswitch 2 off “L” position is for left hand installation.
4. Sensitivity adjustment
1)
Adjust pot “DOWN” for close traveling sensitivity, clockwise is for more force and anti-
clockwise for less force.
2)
Adjust pot “UP” for open traveling sensitivity, clockwise is for more force and anti-clockwise
for less force.
Whilst the door is traveling turn the obstruction sensitivity pot slowly until an overload condition
occurs i.e. door going up stops before reaching the set top limit or door going down auto reverses
before reaching set bottom limit. Cycle the door a few times ensuring an overloading condition is
not registered during normal operation.
5.
Battery Backup (Optional)
(If your battery back-up has a
3
plug connection, have it changed).
Plugs into SP+ & SP-.
PROGRAMMING TRANSMITTERS TO CONTROL BOX
(Max 20)
Press and release K1 learning button below the red LED, the red LED will light up, then press the
transmitter once & the red LED wil go off, press the same transmitter again, the red LED will flash
fast 8 times. The transmitter is now programmed.
•
For more transmitters (max. 20), code them the same as above.
•
If the red LED gives 4 double flashes on pressing the K1 button, the receiver is full.