background image

 

1

   
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 

 

 
 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Base plate-mounting instructions 

 
 
 

 
 
                                  
 
 
 
 
 

 

   

                 

Dts-12 

           ROLLER DOOR OPERATOR 

          INSTALLATION MANUAL 

Comply to: SANS IEC 60 335-2-103 

                                                                      NRCS Cert. no. 88934/002 

 

 

 

DTS SECURITY PRODUCTS CC 

P.O.BOX 3399 

EDENVALE 

1610 

TELEPHONE 086 1000 387 

 

                                                            Spartan      +2711 392 5540 (H/O) 

                                                            Pretoria      +2712 361 5528 

                                                            Alberton     +2711 907 8846 

                                                            Natal           +2731 916 4002 

 

                                               

                                                                       

www.dtssecurity.co.za 

 

Summary of Contents for Dts-12

Page 1: ...INSTALLATION MANUAL Comply to SANS IEC 60 335 2 103 NRCS Cert no 88934 002 DTS SECURITY PRODUCTS CC P O BOX 3399 EDENVALE 1610 TELEPHONE 086 1000 387 Spartan 2711 392 5540 H O Pretoria 2712 361 5528 A...

Page 2: ...ectronic obstruction system that provides safe and reliable operation It is however a legal requirement in some countries to also install a Photo electric sensor across the door way Please check this...

Page 3: ...commended side clearance between door curtain and the inside edge of mounting bracket is 110mm The recommended side clearance between door curtain and the outside edge of mounting bracket is 160mm If...

Page 4: ...nd others where the drum wheel door is less than 135mm from the centre shaft support bracket 1 Release the engage disengage lever on the motor so that it runs free 2 Make sure that there is enough spa...

Page 5: ...ation shown inside looking out Lift door onto mounting brackets ensuring curtain roll is correct way round centralize curtain roll with opening Refer to door installation instructions New installation...

Page 6: ...t cam T controls open position of door Bottom limit cam B controls closed position of door STEP 3 Slightly loosen the three retaining screws so that the cams can be easily moved See Figure 7 Figure 7...

Page 7: ...rol Box Front and check closing and stopping position Figure 9 i Door fully closed ii Door slightly closed STEP 12 If you are achieving the desired stop position then replace the Limit Switch Cover Pl...

Page 8: ...ot UP for open traveling sensitivity clockwise is for more force and anti clockwise for less force Whilst the door is traveling turn the obstruction sensitivity pot slowly until an overload condition...

Page 9: ...opened manually Obstruction Detection During an open cycle if an obstruction is detected the door will stop During a closing cycle if an obstruction is detected the door will reverse to the open posi...

Page 10: ...heck manual operation for correct balance not binding Adjust if necessary Spray silicone lubricant into tracks do not grease Check adjust safety sensitivity setting Check Limits BANGS HARD ON TRACK ST...

Page 11: ...SPEC Motor Type Permanent Magnet D C Motor Voltage 24V DC CONTROL BOARD SPEC Control Board Voltage 24V DC 5V DC Light Glove Voltage 36V 1 5W Receiver specification Receiver type FSK AM Built in RF Fr...

Page 12: ...ion In the event of the goods being supplied by dealer merchant agent or duly appointed installer of DTS Security Products the claim must be directed to that supplier The carriage of goods is for the...

Reviews: