STEP 9 

Manually position door to halfway and re-engage 
the motor drive by moving the manual release lever 
to the “engage” position. 
N.B.:  Door can now only be operated electrically, 
not manually.  If you wish to return to manual 
operation, ensure power is switched off and move 
lever to “disengage” position. 

 

Figure 8 

 

STEP 10 

Switch on power to the Control Box and operate the 
door from PUSH button on the Control Box. 
 
 

IMPORTANT:

  When the door is traveling in the 

“Up” position, hold bottom rail.  The door should 
overload and stop.  If it does not, see that motor 
direction is correct 

You will need to re-adjust the Limit Cams as they 
will be working in a different direction. 
 

STEP 11 

Press Button on Control Box Front and check 
closing and stopping position. 

 

 
Figure 9 
 

 

 
 
i)

 

Door fully closed  

ii)

 

Door slightly closed 

 

STEP 12 

If you are achieving the desired stop position, then replace the Limit Switch Cover Plate.  If not, 
then reset the Limit Cams (Steps 2 to 9) after first turning off the mains power. 

 
STEP 13 

Once the limits have been set, fit the additional security screws (if required) with the door in 
manual mode.  With the door fully closed, mark the panel at the first point where the curtain roll 
touches the drum wheel, on both ends of the curtain (See figure 9). 
 
Raise the door slightly so that the marks can be seen and accessed from inside the garage. 
Fit the security screws through the bottom of a corrugation and into the plastic flange of the drum 
wheel, on both ends of the curtain Tighten securely.   
 

 

 
WARNING! – Do not run door on power through its full travel until the limits are correctly set. 
 
 
 
 
 
 
       

Summary of Contents for Dts-12

Page 1: ...INSTALLATION MANUAL Comply to SANS IEC 60 335 2 103 NRCS Cert no 88934 002 DTS SECURITY PRODUCTS CC P O BOX 3399 EDENVALE 1610 TELEPHONE 086 1000 387 Spartan 2711 392 5540 H O Pretoria 2712 361 5528 A...

Page 2: ...ectronic obstruction system that provides safe and reliable operation It is however a legal requirement in some countries to also install a Photo electric sensor across the door way Please check this...

Page 3: ...commended side clearance between door curtain and the inside edge of mounting bracket is 110mm The recommended side clearance between door curtain and the outside edge of mounting bracket is 160mm If...

Page 4: ...nd others where the drum wheel door is less than 135mm from the centre shaft support bracket 1 Release the engage disengage lever on the motor so that it runs free 2 Make sure that there is enough spa...

Page 5: ...ation shown inside looking out Lift door onto mounting brackets ensuring curtain roll is correct way round centralize curtain roll with opening Refer to door installation instructions New installation...

Page 6: ...t cam T controls open position of door Bottom limit cam B controls closed position of door STEP 3 Slightly loosen the three retaining screws so that the cams can be easily moved See Figure 7 Figure 7...

Page 7: ...rol Box Front and check closing and stopping position Figure 9 i Door fully closed ii Door slightly closed STEP 12 If you are achieving the desired stop position then replace the Limit Switch Cover Pl...

Page 8: ...ot UP for open traveling sensitivity clockwise is for more force and anti clockwise for less force Whilst the door is traveling turn the obstruction sensitivity pot slowly until an overload condition...

Page 9: ...opened manually Obstruction Detection During an open cycle if an obstruction is detected the door will stop During a closing cycle if an obstruction is detected the door will reverse to the open posi...

Page 10: ...heck manual operation for correct balance not binding Adjust if necessary Spray silicone lubricant into tracks do not grease Check adjust safety sensitivity setting Check Limits BANGS HARD ON TRACK ST...

Page 11: ...SPEC Motor Type Permanent Magnet D C Motor Voltage 24V DC CONTROL BOARD SPEC Control Board Voltage 24V DC 5V DC Light Glove Voltage 36V 1 5W Receiver specification Receiver type FSK AM Built in RF Fr...

Page 12: ...ion In the event of the goods being supplied by dealer merchant agent or duly appointed installer of DTS Security Products the claim must be directed to that supplier The carriage of goods is for the...

Reviews: