background image

 

9

 
To master delete all codes 

Press and hold the K1 learning button, the LED will flash 10 times, all transmitter codes held in the 
memory have been erased. 

 

Wiring for external receivers.

 

PCB to Receiver 
+24       24 Volt 
 -           Neg.  
+A         N/O 
 A          Com.   
(Power for any 24 volt DC externals can also be taken from SP- (Neg.) and SP+ (Pos.)  

(If the receiver and the cover red push button don’t work, power down for approximately 5 seconds then re-apply 
power). 

 

N.B.: If a transmitter is lost or stolen please master delete the receiver and re-learn all the 
transmitters again. 

 

OWNER’S MANUAL 

 

DOOR OPERATION 

A roller door equipped with a roller door operator may be operated by any of the following two 
methods: 
By using the hand held Transmitter; 
By depressing the push button on the control box. (Mounted on the wall) 

 

WARNING!

 

Ensure that the Centre Lift Lock is not engaged when the Drive Unit is in the automatic position. 

 
Manual Operation 

In the case of a power failure, the drive unit has an easily accessible manual release lever; the door 
could be opened manually. 

 

Obstruction Detection 

During an open cycle if an obstruction is detected the door will stop. 
During a closing cycle if an obstruction is detected the door will reverse to the open position.   
The sensitivity or the amount of force required to cause an obstruction detection is fully adjustable. 

 

Courtesy Light 

An internal courtesy light is housed within the control box enclosure.  This is activated during an 
open or close cycle and will stay illuminated for approximately 60 seconds. 

 

Automatic Closing. 

When auto close is selected, the door will close after 60 seconds. Please do not use this function 
without installing Photo-beam. 

 

Photo-electric sensor 

The operator includes an interface for the connection of a photo-beam sensor. 
The Photo-beam sensor can be supplied as an accessory option. 

 

OPERATING CONTROLS 

a.

 

Control Box Push Button 

 

Pressing this button will open, close or stop the door. 

b.

 

Hand transmitter 

 

Pressing the programmed transmitter will open, close and stop the door. 

         

 

The hand transmitter is manufactured using the latest surface mount technology and incorporates 4 
functional buttons.  This enables the user to remotely control up to 4 separate operators from the 
one transmitter. 

Summary of Contents for Dts-12

Page 1: ...INSTALLATION MANUAL Comply to SANS IEC 60 335 2 103 NRCS Cert no 88934 002 DTS SECURITY PRODUCTS CC P O BOX 3399 EDENVALE 1610 TELEPHONE 086 1000 387 Spartan 2711 392 5540 H O Pretoria 2712 361 5528 A...

Page 2: ...ectronic obstruction system that provides safe and reliable operation It is however a legal requirement in some countries to also install a Photo electric sensor across the door way Please check this...

Page 3: ...commended side clearance between door curtain and the inside edge of mounting bracket is 110mm The recommended side clearance between door curtain and the outside edge of mounting bracket is 160mm If...

Page 4: ...nd others where the drum wheel door is less than 135mm from the centre shaft support bracket 1 Release the engage disengage lever on the motor so that it runs free 2 Make sure that there is enough spa...

Page 5: ...ation shown inside looking out Lift door onto mounting brackets ensuring curtain roll is correct way round centralize curtain roll with opening Refer to door installation instructions New installation...

Page 6: ...t cam T controls open position of door Bottom limit cam B controls closed position of door STEP 3 Slightly loosen the three retaining screws so that the cams can be easily moved See Figure 7 Figure 7...

Page 7: ...rol Box Front and check closing and stopping position Figure 9 i Door fully closed ii Door slightly closed STEP 12 If you are achieving the desired stop position then replace the Limit Switch Cover Pl...

Page 8: ...ot UP for open traveling sensitivity clockwise is for more force and anti clockwise for less force Whilst the door is traveling turn the obstruction sensitivity pot slowly until an overload condition...

Page 9: ...opened manually Obstruction Detection During an open cycle if an obstruction is detected the door will stop During a closing cycle if an obstruction is detected the door will reverse to the open posi...

Page 10: ...heck manual operation for correct balance not binding Adjust if necessary Spray silicone lubricant into tracks do not grease Check adjust safety sensitivity setting Check Limits BANGS HARD ON TRACK ST...

Page 11: ...SPEC Motor Type Permanent Magnet D C Motor Voltage 24V DC CONTROL BOARD SPEC Control Board Voltage 24V DC 5V DC Light Glove Voltage 36V 1 5W Receiver specification Receiver type FSK AM Built in RF Fr...

Page 12: ...ion In the event of the goods being supplied by dealer merchant agent or duly appointed installer of DTS Security Products the claim must be directed to that supplier The carriage of goods is for the...