I n s t a l l a t i o n & P r o g r a m m i n g M a n u a l
46
Extensions to ring for exchange lines and door phones
Add extension to ring for exchange line during day
System Settings
Incoming Ring
Set Exch x day mode
Stop extension ringing for exchange line during day
System Settings
Incoming Ring
Set Exch x day mode
Add extension to ring for exchange line during night
System Settings
Incoming Ring
Set Exch x night mode
Stop extension ringing for exchange line during night
System Settings
Incoming Ring
Set Exch x night mode
Reset all extensions to ring for all exchange lines
Extensions to ring for MSN numbers
Add an extra extension to ring on MSN number
Stop an extension ringing on MSN number
Extensions to ring in extension groups
Add an extension to ringing in extension group
Remove an extension from ringing in extension group
Ringing cadences
Swap internal and external ring cadence
Use normal internal and external ring cadence
Use Normal Ring Cadence for calls on line 1
System Settings
Miscellaneous
Exch 1 normal cadence
Use Different Ring Cadence for calls on line 1
System Settings
Miscellaneous
Exch 1 special cadence
Security Alarm Programming
Description
The system has two independent alarm sensor ports. These can support single contacts, multiple
contacts, passive infra-red devices, outputs from current alarm systems or smoke detectors, in series
for normally closed or in parallel for normally open contacts. The system can ring extensions
internally and dial out to up to two different external numbers when the alarm is activated, with a
voice message if the fax/voice message option card is fitted.
Alarm Sensors
The system provides two alarm ports to which alarm sensors may be attached, see Figure 4-3 on
page 54. These may be programmed and set independently as normally open or normally closed
contacts. If the alarm contact changes from it's normal state then the alarm is triggered. An optional
entry delay of 90 seconds may be added to give the user time to disarm the alarm when entering the
alarmed area. An alarm loop may also be programmed as a social alarm. In this case the alarm is
triggered if the loop does not change state for a period of 24 hours. Alarm sensor 2 can also operate
as a switch to select between day and night operation modes, for information see the section 'Manual
Day/Night Setting with switch' on page 39.
Alarm Notification
Whenever an alarm is triggered then the system can ring internal extensions, ring external telephone
numbers, or both.
Internal notification will ring all extensions for a period of 30 seconds. This ring may be
stopped temporarily by going off-hook at any extension. This internal alarm repeats every 5
minutes until the alarm is correctly reset.
External notification will make an external call and can use a voice message or a special
alarm tone to warn the user of the alarm. Up to 2 external numbers may be dialled a
PIN
line delay ext.
Key
line =
0 for all exchange lines r
1 - 6 for single exch. line
7 for the Door phones
delay =
0 for no ringing
1 for immediate ringing
2 - 9 for ringing after 10,
15 … 45 seconds
MSN_entry =
11-18, 21-24 for
extension with
programmed MSN
ext =
extension number 11-24
or 1* for all extensions
group =
0 – 3 for extension
groups 80 - 83
PIN
line
ext.
PIN
line delay ext.
PIN
line
ext.
PIN
MSN_entry, ext
MSN_entry, ext
group, ext
group, ext
PIN
PIN