8 Channel Amplifier Matrix Controller
17
Explanation on priority of channels to call standby amplifier: if the main power amplifier of each channel is in
abnormal condition, the corresponding standby power amplifier which is in normal connection will be
automatically called.
d)
When the device is under 4 mains and multiple standbys working mode, there are 9 default external
power amplifiers. As the main interface shown in the Figure 3-20, Channel CH1 – CH4 are four
working zones, and the standby power amplifier of each channel (see Table 3-4 for details). Now the
zone setting interface is as shown in Figure 3-21:
Figure 3-20 Main interface of 4 mains and multiple standbys working mode
Figure 3-21 Zone setting interface of 4 mains and multiple standbys working mode
Channels
Main amplifier
Standby amplifier can be called
CH1
AMP1
AMP5
、
AMP6
、
AMP7
、
AMP8
、
AMP9
CH2
AMP2
AMP5
、
AMP6
、
AMP7
、
AMP8
、
AMP9
CH3
AMP3
AMP5
、
AMP6
、
AMP7
、
AMP8
、
AMP9
CH4
AMP4
AMP5
、
AMP6
、
AMP7
、
AMP8
、
AMP9
Table 3-4