8 Channel Amplifier Matrix Controller

 

C. Linkage Instruction 

3.1 System connection diagram 

PC1021X 8 channel amplifier matrix controller performs in the best way when it works with DA8250 digital 

amplifier. The connection diagram is as below: 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

COM  100V

CHANNEL-9

COM  100V

COM  100V

COM  100V

COM  100V

COM  100V

COM  100V

COM  100V

COM  100V

CHANNEL-8

CHANNEL-7

CHANNEL-6

CHANNEL-5

CHANNEL-4

CHANNEL-3

CHANNEL-2

CHANNEL-1

CH-7

CH-8

CH-5

CH-6

CH-3

CH-4

CH-1

CH-2

CH9

GND IN

AC220V

~50/60Hz  3000W

电源开关

  型号:DA8250
  品名:八主一备智能广播功放
制造商:广州市迪士普音响科技有限公司

2000m

CAUTION!

RISK OF ELECTRIC SHOCK

DO NOT OPEN

警告

请勿打开,以免触电

IN

IN

IN

IN

IN

IN

IN

IN

Audio input 

PC1021X 8 channel amplifier matrix controller 

DA8250 digital amplifier 

AMP INPUT

SPEAKER OUTPUT

OUT

GND

CH9

CH8

CH7

CH6

CH5

CH4

CH3

CH2

CH1

CH1

CH2

CH3

CH4

CH5

CH6

CH8

CH7

COM1  CH1

COM2  CH2

COM3  CH3

COM4  CH4

COM5  CH5

COM6  CH6

COM7  CH7

COM8  CH8

COM9  CH9

AC220/50Hz/30W/F2AL

ON

OFF

GND

GND

GND

GND

GND

GND

GND

GND

IN

GND

IN

GND

IN

GND

IN

GND

IN

GND

IN

GND

IN

GND

IN

GND

COM1  CH1

COM2  CH2

COM3  CH3

COM4  CH4

COM5  CH5

COM6  CH6

COM7  CH7

COM8  CH8

型号:

PC1021X

品名:八通道功放矩阵控制器

制造商:广州市迪士普音响科技有限公司

2000M

CAUTION!

RISK OF ELECTRIC SHOCK

DO NOT OPEN

警告

请勿打开,以免触电

OUT

OUT

OUT

OUT

OUT

OUT

OUT

OUT

SEC

PRI

      N

ur Sic

he
ru

n

g

 2

5

0

V

U

s

e

 O

n

ly

 W
ith

 A

 2

5

0

V

 F

u

s

e

E

m

p

lo

y

e

r U

n

lq

u

e

m

e

n

t A

v

e

c

         Fus

ib

le

 D

e

 2

5

0

V

LINK IN

LINK OUT

Summary of Contents for PC1021X

Page 1: ...10 PCX 5A 2 4 6 8 10 PCX 5A 2 4 6 8 10 PCX 5A 2 4 6 8 10 PCX 5A 2 4 6 8 10 PCX 5A 2 4 6 8 10 PCX 5A STATE SIG STATE SIG STATE SIG STATE SIG STATE SIG STATE SIG STATE SIG STATE User s Manual Welcome t...

Page 2: ...nstructions and other contents of the 8 Channel Amplifier Matrix Controller PC1021X device The user shall read the Instructions carefully and operate the device following the indications in the Instru...

Page 3: ...the device Do not impose an excessive force when operating the switch buttons or connecting the external audio equipment Avoid any foreign matter paper metal etc from entering the device through gap...

Page 4: ...UP 5 4 2 MAIN INTERFACE INSTRUCTIONS 5 4 3 INTERFACE OPERATION INSTRUCTIONS 7 1 SYSTEM SETTINGS 7 2 EQUALIZER AND MASTER VOLUME SETTINGS 8 3 AUDIO OUTPUT LEVEL SETTINGS 9 4 MONITORING ON OFF AND VOLUM...

Page 5: ...rt hot plug for the power switching modules can plug the power switching modules with electricity on after switching off all the zones on the interface without powering off the device With real time p...

Page 6: ...A STATE 2 4 6 8 10 SIG PCX 5A STATE 1 5 band output level indicator The indicator shows the volume of output dynamically 2 Screws for switching main and standby power modules Loosing the screws manual...

Page 7: ...OT OPEN OUT OUT OUT OUT OUT OUT OUT OUT SEC PRI Nur Sicherung 250V Use Only With A 250V Fuse Employer Unlquement Avec Fusible De 250V 1 3 4 6 2 5 7 LINK IN LINK OUT 1 Dante interface optional With CAT...

Page 8: ...SK OF ELECTRIC SHOCK DO NOT OPEN IN IN IN IN IN IN IN IN Audio input PC1021X 8 channel amplifier matrix controller DA8250 digital amplifier AMP INPUT SPEAKER OUTPUT OUT GND CH9 CH8 CH7 CH6 CH5 CH4 CH3...

Page 9: ...2 Main interface instructions The display will show the main interface automatically the factory setting is 8 main and 1 standby amplifier modes As figure 2 1 shown the status of 8 zones figure 2 1 sh...

Page 10: ...determine the load state If the zone is in open state 1 if the audio input signal of the channel disappears 10s the channel will begin self check to test the load state The channel will be closed aut...

Page 11: ...e CH1 zone status bar Figure 3 1 CH1 zone setting interface The following operations can be conducted in CH1 setting interface 1 System settings 1 Working mode settings Click the icon in the zone sett...

Page 12: ...ice life of the screen the setting range of fixed backlight time is 30s 240s Figure 3 2 System setting interface 2 Equalizer and master volume settings In the zone setting interface shown in Figure 3...

Page 13: ...wn box will appear Click and select one of them according to requirements Figure 3 5 Zone setting interface 4 Monitoring ON OFF and volume settings Slide the monitoring slide to ON status the system d...

Page 14: ...g interface as shown in Figure 3 7 and the channel main and standby switch interface as shown in Figure 3 8 pops up Click the yes button to turn on the current channel main and standby switch If you w...

Page 15: ...wer amplifier of the current channel returns to normal the system will automatically restore the main power amplifier If the current channel master standby switch is OFF the channel is no longer with...

Page 16: ...gain the window of manual call setting pops up as shown in Figure 3 12 the function of manual adjustment will be turned off by clicking the ok button Click yes to switch off the manually call function...

Page 17: ...current amplifier is a standby amplifier and it is free currently Green icon means the current amplifier is working normally Gary icon means the current amplifier is now with no amplifier Red icon mea...

Page 18: ...ifier can be called Priority of channels to call standby amplifier CH1 AMP1 AMP9 High Low CH2 AMP2 AMP9 CH3 AMP3 AMP9 CH4 AMP4 AMP9 CH5 AMP5 AMP9 CH6 AMP6 AMP9 CH7 AMP7 AMP9 CH8 AMP8 AMP9 Table 3 1 Ex...

Page 19: ...mplifiers As the main interface shown in the Figure 3 16 Channel CH1 CH4 are four working zones and the standby power amplifier of each channel is AMP 9 see Table 3 2 for details Now the zone setting...

Page 20: ...longer has main and standby switching function c When the device is under 4 mains and 4 standbys working mode there are 8 default external power amplifiers As the main interface shown in the Figure 3...

Page 21: ...lifiers As the main interface shown in the Figure 3 20 Channel CH1 CH4 are four working zones and the standby power amplifier of each channel see Table 3 4 for details Now the zone setting interface i...

Page 22: ...ower amplifiers is from AMP5 to AMP9 6 Zone load settings Click the zone load setting button on the zone setting interface as shown in Figure 3 22 and the window of zone load setting as shown in Figur...

Page 23: ...ss the buzzer is on for 1 second 3 Enter the calibration mode and click the specified position of the touch screen to calibrate the touch screen according to the cross line 4 Return to the screen afte...

Page 24: ...g any connection Do not open the case to repair the device without authorization in case of any fault in order to avoid the accident or aggravate the damage of the device Do not put any corrosive chem...

Page 25: ...st Quantity 1 User s manual 1 copy 2 Warranty card 1 copy 3 Certificate 1 copy 4 10A MP P power cord 1 set 5 2P green plug 17 pieces 6 2P plug lug terminal 7 62MM 17 pieces 7 Washer black 4 pieces 8 5...

Page 26: ...the cover of the machine to prevent the electric shock If necessary it shall be repaired by the professional with the professional certificate The terminal marked with a symbol in the device indicates...

Reviews: