P r o g r a m m i n g W o r k s h e e t s
37
[365] Opening/Closing Communicator Call Directions
(Section 5.5 “Communicator – Dialing” on page 16)
Default
Option ON
OFF
ON
I________I
1
1st Telephone Number
Disabled
OFF
I________I
2
2nd Telephone Number
Disabled
OFF
I_______I
3-8
For future use
[367] System Maintenance Alarm/Restore Communicator Call Directions
(Section 5.5 “Communicator – Dialing” on
Default
Option ON
OFF
ON
I________I
1
1st Telephone Number
Disabled
OFF
I________I
2
2nd Telephone Number
Disabled
OFF
I_______I
3-8
For future use
[368] System Test Transmissions Communicator Call Directions
(Section 5.5 “Communicator – Dialing” on page 16)
Default
Option ON
OFF
ON
I________I
1
1st Telephone Number
Disabled
OFF
I________I
2
2nd Telephone Number
Disabled
OFF
I_______I
3-8
For future use
[370] Communication Variables
Default
Section
Page #
003
I_______I_______I_______I
Swinger Shutdown (Alarms and Rest) (001-014 Transmissions, 000=disabled)
003
I_______I_______I_______I
Swinger Shutdown (Tampers and Rest)(001-014 Transmissions, 000=disabled)
003
I_______I_______I_______I
Swinger Shutdown (Maint and Rest)
(001-014 Transmissions, 000=disabled)
000
I_______I_______I_______I
Transmission Delay
(001-255 seconds)
030
I_______I_______I_______I
AC Failure Communication Delay
(001-255 minutes)
003
I_______I_______I_______I
TLM Trouble Delay
(No. of checks required - valid entries 003 - 255) 5.12
030
I_______I_______I_______I
Test Transmission Cycle (land line)
(001-255 minutes/days)†
030
I_______I_______I_______I
Test Transmission Cycle (LINKS)
(001-255 days)
007
I_______I_______I_______I
Zone Low Battery Transmission Delay (000-255 days)
†Depends on programming in section [702], option [3].
NOTE: To disable the AC failure communications delay, program [000].
[371] Test Transmission Time of Day
(Section 5.14 “Test Transmission” on page 23)
NOTE: If the land line test transmission cycle is programmed in minutes (section [702], option [3]), this section will not affect the land
line test transmission cycle.
Default
9999
I_______I_______I_______I_______I
(Valid entries are 0000-2359, 9999 to disable)
[380] First Communicator Option Code
Default Option
ON
Off
Section
Page
#
ON
I_______I
1
Communications Enabled
Communications Disabled
OFF
I_______I
2
Restorals on Bell Time-out
Restorals Follow Zones
OFF
I_______I
3
Pulse
Dialing
DTMF
Dialing
ON
I_______I
4
Switch to Pulse Dialing on 5th Attempt
DTMF Dial For All Attempts
OFF
I_______I
5
3rd Telephone Number enabled
3rd Telephone Number disabled
OFF
I_______I
6
Alternate Dial (1st and 3rd)
Call 1st Number, Backup to 3rd
OFF
I_______I
7-8
For future use
Summary of Contents for Power608