32
Advanced System Programming
(Section 5.3 “Zone Attributes” on page 15)
Zone Attribute Defaults (Y = Option ON; N = Option OFF):
Section
Zone #
Zone
1
2
3
4
5
6
7
8
Type*
[101]
1
( )
I________I
I________|
I________|
I________|
I________|
I________|
I________|
I________I
[102]
2
( )
I________I
I________|
I________|
I________|
I________|
I________|
I________|
I________I
[103]
3
( )
I________I
I________|
I________|
I________|
I________|
I________|
I________|
I________I
[104]
4
( )
I________I
I________|
I________|
I________|
I________|
I________|
I________|
I________I
[105]
5
( )
I________I
I________|
I________|
I________|
I________|
I________|
I________|
I________I
[106]
6
( )
I________I
I________|
I________|
I________|
I________|
I________|
I________|
I________I
[107]
7
( )
I________I
I________|
I________|
I________|
I________|
I________|
I________|
I________I
[108]
8
( )
I________I
I________|
I________|
I________|
I________|
I________|
I________|
I________I
*Record here based on programming in section [001]
Attribute:
1
2
3
4
5
6
7
8
ON
Audible
Steady
Chime
Bypass
Force
Swing
Tx. Delay
Wireless Zn.
OFF
Silent
Pulsed
No
No
No
No
No
No
Zone Type:
00 Null Zone
N
N
N
N
N
N
N
N
01 Delay 1
Y
Y
Y
Y
N
Y
N
N
02 Delay 2
Y
Y
Y
Y
N
Y
N
N
03 Instant
Y
Y
Y
Y
N
Y
N
N
04 Interior
Y
Y
N
Y
N
Y
N
N
05 Int. Stay/Away
Y
Y
N
Y
Y
Y
N
N
06 Dly. Stay/Away
Y
Y
N
Y
Y
Y
N
N
07 Dly. 24hr Fire (Hardw.)
Y
N
N
N
N
N
N
N
08 Stand. 24hr Fire (Hardw.)
Y
N
N
N
N
N
N
N
09 24hr Superv.
N
Y
N
N
Y
N
N
N
10 24hr Superv. Buzzer
N
Y
N
Y
N
N
N
N
11 24hr Burglary
Y
Y
N
Y
N
N
N
N
12 24hr Holdup
N
Y
N
N
N
N
N
N
13 24hr Gas
Y
N
N
N
N
N
N
N
14 24hr Heat
Y
N
N
N
N
N
N
N
15 24hr Medical
Y
Y
N
N
N
N
N
N
16 24hr Panic
Y
Y
N
N
N
N
N
N
17 24hr Emergency
Y
Y
N
N
N
N
N
N
18 24hr Sprinkler
Y
Y
N
N
N
N
N
N
19 24hr Water
Y
Y
N
N
N
N
N
N
20 24hr Freeze
Y
Y
N
N
N
N
N
N
21 24hr Latching Tamper
Y
Y
N
N
N
N
N
N
22 Momentary Keyswitch
N
N
N
N
Y
N
N
N
23 Maintained Keyswitch
N
N
N
N
Y
N
N
N
25 Interior Delay
Y
Y
N
Y
N
Y
N
N
27 Push to Set
N
N
N
N
Y
N
N
N
28 24-hour Bell/Buzzer
Y
Y
N
Y
N
N
N
N
87 Dly. 24hr Fire (Wireless)
Y
N
N
N
N
N
N
Y
88 Stand. 24hr Fire (Wireless)
Y
N
N
N
N
N
N
Y
Summary of Contents for Power608
Page 4: ...ii PC5008 Wiring Diagram...
Page 50: ...46 NOTES...