background image

7

Installing Cellular/Ethernet Communicator in 

3G Alarm Communicator Installation Manual

Keybus Connection

4. Install the Keybus cable between Communicator and Panel as follows:

WARNING

: D

NOT 

CONNECT 

K

EYBUS 

R

ED

 

OR 

B

LK

 

WIRES TO THE 

P

ANEL OR 

THE 

C

OMMUNICATOR 

T

ERMINAL 

B

LOCKS

.

a. Attach a wire from the Communicator 

YEL

 terminal to the panel 

YEL

 terminal.

b. Attach a wire from the Communicator 

GRN

 terminal to the panel 

GRN

 terminal.

Install Network Cable (TL2603G/TL260 only)

5. Route the CAT 5 Ethernet cable through back of the panel and plug it into the Communicator’s

RJ45 jack.

NOTE: 

Before leaving the premises the Ethernet communication lines must first be connected to 

an approved (acceptable to local authorities) type NID. All wiring shall be performed according to 

the local electrical codes.
6. Perform the following steps for initial power on of the panel with Communicator installed:

a. Reconnect the AC power, telephone line, and battery 

+

 connector to the panel. 

(The Communicator and Panel will power up together).

b. Observe that the Communicator’s red and yellow LEDs are flashing together while it initial-

izes. The red and yellow LEDs will continue to flash until the Communicator has success-

fully communicated to all programmed receivers.

NOTE: 

Initialization may take several minutes to complete. red and yellow LEDs will flash 

together during initialization. Do not continue to next step until the red and yellow LEDs have 

stopped flashing. (If only the yellow LED is flashing, there is a Communicator trouble and the 

Green LEDs are not valid for Communicator Placement Test). Correct trouble indicated by flashes 

on yellow LED before continuing. (See Table 9  for troubleshooting assistance).
7. Perform the Communicator Placement Test below.
8. Mount the Panel in final location indicated by placement test.

Figure 3:Communicator Wiring Diagram

AUDIO/DEFAULT

DSC

UA601

PC-LINK

PC-LINK

COM

TL2603G(R)
TL260(R)
3G2060(R)

AC

   

AC

Z1   COM   Z2    Z3   COM  Z4    Z5   COM     Z6    Z7    COM   Z8

AUX+

BELL +

PGM1      PGM3

RING

T-1

PC1616/1832/1864

3G Radio

+

-

UA503

1

To external antenna

                                    

Input Ratings from 

Bell +

:  

+11.1V ~ +12.6 VDC         
100mA standby; 400mA alarm

DSC Panel min. power requirements:
- 16 VAC 40 VA transformer; 
- 12 VDC 7Ah battery

+

-

  

External Bell/Siren

Black

Black

Jumper pins 4 and 5 
to reset.

L
o
c
k

1

GRN

(not used)

   From NID

TL2603G(R)

 

 

Use only CAT5

 

 

Supervised

RJ-45

YEL

COM

PWR

GRN

YEL

TIP

R-1

BLK

RED

AUX - 

BELL -

EGND

Do NOT
connect
Red or Black
Keybus wires!

TX+

GND

TX-

RX+

RX-

SHLD

Green

Yellow

SIM

Network Link

                                           

 

YELLOW

XX

PGM2      PGM4

Maximum cable length

100 m (328 ft)

PWR

Summary of Contents for 3G2060

Page 1: ...Dual path Alarm Communicator International TL260 Internet Alarm Communicator International INSTALLATION MANUAL V3 0 Warning This manual contains information on limitations regarding product use and f...

Page 2: ......

Page 3: ...Options 21 Ethernet Options 22 Cellular Receiver 1 Options 22 Cellular Receiver 2 Options 23 Cellular Options 24 System Information Read Only 25 System Reset Defaults 26 Communicator Status Initializ...

Page 4: ...occupants or their belongings Motion Detectors Motion detectors can only detect motion within the designated areas as shown in their respective installation instructions They cannot discriminate betwe...

Page 5: ...rk TL2603G Is a Dual path HSPA 3G Internet Alarm Communicator that sends alarm communica tion to SG System I II III IV and 5 central station receivers through Internet or a HSPA 3G GPRS digital cellul...

Page 6: ...ia cellular and Internet Communicator Frequency Bands by Market Table 1 2G Frequency Bands All Markets Table 2 3G Frequency Bands Europe Table 3 3G Frequency Bands Australia New Zealand and Brazil Tab...

Page 7: ...unicator to link up with your computer Type the SMS message in to your cell phone and send to the Communicator s cellular phone number Then Click OK 6 The SMS message will trigger the unit to establis...

Page 8: ...used within an environment that provides the pollution degree max 2 overvoltages category II in non hazardous indoor locations only This manual shall be used with the Installation Manual of the panel...

Page 9: ...es on the Communicator with the 4 standoffs protruding from the bracket Push the Communi cator firmly and evenly onto the standoffs until it is securely attached to the mounting bracket d Remove the p...

Page 10: ...ower lim ited wiring and power limited wiring 3 To electrically connect the Communicator to the panel perform the following steps See Figure 3 a Disconnect both AC power and battery connections from t...

Page 11: ...until the Communicator has success fully communicated to all programmed receivers NOTE Initialization may take several minutes to complete red and yellow LEDs will flash together during initializatio...

Page 12: ...tructions regarding the installation of the antenna All the wiring of the equipment shall be fully compliant with the local rules and regulations 3 If required install the antenna extension and perfor...

Page 13: ...303 program the central station telephone number that will be used for the cellular Ethernet Communicator Valid entries are a A valid telephone number signals will be routed to the central station us...

Page 14: ...highest trouble will indicate if present This will continue until all troubles have been cleared yellow LED is not flashing The following paragraphs describe the conditions associated with the trouble...

Page 15: ...ogrammed in Sections 205 and 215 Receiver Supervision Trouble 8 Flashes This trouble is indicated when receiver supervision is enabled and communication between the Communicator module and the receive...

Page 16: ...fault pins 4 and 5 Green LEDs will stop flashing 6 Replace the panel cover NOTE The communicator has now been reset to the factory default values Firmware Update The firmware of the device can be upda...

Page 17: ...he Hub Router Switch is ON If link light is OFF try restarting the Hub Router Switch If DHCP is used ensure that the unit has an assigned IP address from the server In Section 851 992 verify a valid I...

Page 18: ...erver will assign the subnet mask for this Section and the programmed value will be ignored 003 Ethernet Gateway IP Address Default 000 000 000 000 Enter the Ethernet Gateway IP address of the Communi...

Page 19: ...hernet Receiver 2 and Cellular Receiver 2 at the same time As long as the event is successfully communicated to 1 of the 2 paths Ethernet or Cellular the Communicator will move on to the next event NO...

Page 20: ...t 000 000 000 000 Enter the IP address for DNS Server 1 Format is 4 fields each field is a 3 digit decimal Valid range 000 255 NOTE If no value is programmed and DHCP is used the DHCP Server will conf...

Page 21: ...50 or higher 022 Communications Format Default 04 Program 03 for Contact ID CID Program 04 for SIA The module can be configured to send Events in SIA or CID format The SIA communication format follow...

Page 22: ...ceiver it will backup to the secondary receiver If the test transmission fails to the secondary receiver an FTC trouble will be generated Interval 2 If the test transmission fails to the secondary rec...

Page 23: ...mmunicator Firmware Update Begin Default FF Program 00 to disable this event transmission or FF to enable This event will occur when the communicator firmware update begins 034 Communicator Firmware U...

Page 24: ...a unique DNIS 103 Ethernet Receiver 1 Address Default 127 000 000 001 The default address enables the Communicator to operate in Unattended Mode Unattended Mode is used when a receiver is not availabl...

Page 25: ...lt 000 000 000 000 Programming the Ethernet Receiver 2 IP address with 000 000 000 000 will disable Ethernet Enter the Ethernet receiver 2 IP address This address will be provided by your central stat...

Page 26: ...d when transmitting heartbeat signals to the central station receiver Signals received from the control panel will use the control panel account number Valid range 0000000001 FFFFFFFFFE Programming al...

Page 27: ...entral station Valid range 000000 099999 Values are entered as a 0 followed by the 5 digit DNIS value Format is BCD NOTE Each Ethernet Cellular receiver must be programmed with a unique DNIS 213 Cellu...

Page 28: ...Default 000000 This value represents the interval in between test transmissions in minutes Valid range 000000 999999 minutes Once the unit has sent the initial periodic test transmission all future te...

Page 29: ...will display the IP address of the Ethernet Gateway This value is programmed in Sec tion 003 or assigned by DHCP 994 Cellular IP Address This section will display the current dynamic IP address assig...

Page 30: ...rming the update This allows it to communicate with the Central Station Section 983 will get updated with a 0x0A reason code indicating communication is in progress During Panel Firmware Update if pan...

Page 31: ...nal status of the network 3 Digits 4 5 Trouble Indicator displays the type of issue on the communicator or modules associated with and connected to communicator 4 Digit 6 Reserved displayed a an F or...

Page 32: ...stall an exter nal antenna extension kit 06 Ethernet Trouble Check with your ISP to confirm Internet service is active in your area Ensure your Ethernet cable is securely inserted into the RJ45 jack o...

Page 33: ...This code could be followed with 567 if Receivers 2 3 and 4 are initialized where applicable If the radio initialization status code does not indicate any problems proceed with installation as per thi...

Page 34: ...ellular Default ON 007 DNS Server IP 1 Default 000 000 000 000 ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ 008 DNS Server IP 2 Default 000 000 000 000 ____ ____ ____ ____ ____ ____ ___...

Page 35: ...0000000 Valid range 0000000001 FFFFFFFFFE ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ 112 Ethernet Receiver 2 DNIS Default 000000 Valid range 000000 0FFFFF ____ ____ ____ ____ ____ ____ 113 Ethe...

Page 36: ...lular Test Transmission Time of Day Default 9999 Valid range 00 23 hrs HH 00 59 min MM ____ ____ ____ ____ 225 Cellular Test Transmission Cycle Default 000000 Valid range 000000 999999 minutes ____ __...

Page 37: ...active Enabled Default ON 325 SMS Telephone Number 5 Toggle Options ____ 1 SMS NotificationAlarm Restore Default ON ____ 2 SMS Notification Tamper Restore Default ON ____ 3 SMS Notification Opening Cl...

Page 38: ...___________________________ 376 User 16 Label Default User 16 ________________________________ 377 User 17 Label Default User 17 ________________________________ 378 User 18 Label Default User 18 ____...

Page 39: ...________________________________ 425 Zone 25 Label Default Zone 25 ________________________________ 426 Zone 26 Label Default Zone 26 ________________________________ 427 Zone 27 Label Default Zone 2...

Page 40: ...store Default Gas Carbon Monoxide Restore ________________________________ 511 HeatAlarm Default High TemperatureAlarm ________________________________ 512 Heat Alarm Restore Default High Temperature...

Page 41: ...Delinquency Default Delinquency ________________________________ 557 General System Trouble Default General System Trouble ________________________________ 558 General System Trouble Restore Default...

Page 42: ..._________ 613 Bypass Default Bypass ________________________________ 614 Unbypass Default Unbypass ________________________________ 615 Status Request Default Status Request __________________________...

Page 43: ...__ ____ 995 SIM Number ____________________________________ 996 Cellular Telephone Number This number is required for DLS and Firmware upgrades ____________________________________ 997 IMEI Number ___...

Page 44: ...d printed materials any upgrades and this EULA and provided the recipient agrees to the terms of this EULA If the SOFTWARE PRODUCT is an upgrade any transfer must also include all prior versions of th...

Page 45: ...ducts disassembled or repaired in such a manner as to adversely affect performance or prevent adequate inspection or testing to verify any warranty claim Access cards or tags returned for replacement...

Page 46: ......

Page 47: ......

Page 48: ...603G EU 3G2060 EU TL260 module conforms with radiated emissions levels for Class B equipment as per standards EN61000 6 3 EN55022 CISPR22 4 The TL2603G EU 3G2060 EU TL260 module uses AES128 encryption...

Reviews: