16
Ethernet/Cellular Programming Options
3G Alarm Communicator Installation Manual
[2]
Ethernet 2 Receiver Enabled.
Default (ON) (OFF for 3G2060).
ON
: Ethernet Receiver 2 is enabled.
OFF
: Ethernet Receiver 2 is disabled.
[3] Reserved. ( ).
[4]
Cellular 1 Receiver Enabled.
Default
(ON).
(OFF for TL2603G/TL260)
ON
: Cellular Receiver 1 is enabled.
OFF
: Cellular Receiver 1 is disabled.
[5]
Cellular 2 Receiver Enabled.
Default
(ON).
(OFF for TL2603G/TL260)
ON
: Cellular Receiver 2 is enabled.
OFF
: Cellular Receiver 2 is disabled.
[6] Reserved ( ).
[7] DLS Over Cellular.
Default (ON).
NOTE:
Program this toggle as OFF if you want to completely disable DLS from using the Cellu-
lar path.
ON
: DLS is enabled on the Cellular path.
OFF
: DLS is disabled on the Cellular path.
NOTE:
If this Toggle is OFF, DLS sessions will occur on the Ethernet path only, regardless of Pri-
mary Path set in Section [005] Toggle Option [4]. If it is ON then the Communicator will connect
to the Primary path first for DLS and if the session fails, the Secondary path will be used.
[8] Reserved ( ).
[007] DNS Server IP 1
Default (000.000.000.000)
Enter the IP address for DNS Server 1. Format is 4 fields, each field is a 3 digit decimal. Valid
range: 000-255.
NOTE:
If no value is programmed and DHCP is used, the DHCP Server will configure the
address. If an address is programmed and DHCP is used, the address that you program will be
used instead of the DHCP address.
[008] DNS Server IP 2
Default (000.000.000.000)
Enter the IP address for DNS Server 2. Format is 4 fields, each field is a 3 digit decimal. Valid
range: 000-255.
NOTE:
If no value is programmed and DHCP is used, the DHCP Server will assign this value. If
an address is programmed and DHCP is used, the address that you program will be used instead of
the DHCP address.
Programming Options
[011] Installer Code
Default (CAFE)
Program your installer code for this Communicator module. The installer code will be required
when programming the Communicator module. Valid range: 0000 - FFFF.
[012] DLS Incoming Port
Default (0BF6/3062)
The DLS Incoming Local Port (listening port) is the port DLS IV will use when connecting to the
Communicator. If a router or gateway is used, it must be programmed with a Transmission Control
Protocol (TCP) port forward for this port to the Communicator module IP address. Valid range:
0000 - FFFF.