4
1.3 SYSTEM OPERATION SUMMARY TABLE
ΔPress = supply pressure - tank pressure
1.3.1 MULTIPLIER ON/OFF
AIR SUPPLY PRESSURE
TANK PRESSURE DURING
OPERATION
AIR MULTIPLIER
6 bar
>
4,5 bar
on
<4,5 bar
off
1.4 Schematic Operation Aerosol Flow Rate and Consumption
Note: External is possible In the double nozzle version. Remote HP piloting (from CNC) by inserting an ON/OFF solenoid valve
OPERATING CONDITIONS
VORTEX 1
VORTEX 2
EXTRA AIR
AEROSOL DENSITY
PRESSURE
TANK
ΔPress. >1<=2
NORMAL TOOLS
ON
OFF
OFF
NORMAL
NORMAL
ΔPress. >2
BIG TOOLS
ON
OFF
ON
LOW
LOW
ΔPress.=1
SMALL MEDIUM TOOLS
ON
ON
OFF
NORMAL HIGH
NORMAL
ΔPress.<1
SMALL TOOLS
OFF
ON
OFF
HIGH
HIGH
AEROSOL FLOW AND CONSUMPTION
DEAD ZONE
NO AEROSOL
ZONE
HIGH
PRESSURE
ZONE
HYBRID
PRESSURE ZONE
NORMAL
PRESSURE ZONE
WITH
EXTRA AIR
(4)
(3)
(1)
(2)
Zone (4
)
Zone (3
)
Zone (1
)
Zone (2
)