7.2.3 TANK FILLING
7.2.3.1 FIRST FILLING
During the first filling, it must be ensured that there is
no residual pressure inside the tank. (
Ref. par.9.1
).
The oil must be poured into the tank through the
special inlet (OIL RECHARGE).
The "maximum" sign (B) on the filling indicator must
under no circumstances be exceeded.
7.2.3.2 SUBSEQUENT FILLINGS
When the oil reaches the "minimum" level (A),
MaXtreme
must be refilled. If the unit is in operation,
switch it off and eliminate the residual pressure
(
Ref.par.9.1
). Then proceed as described in
7.2.3.1
FIRST FILLING UP.
If connected in analogue mode with the minimum
level alarm, the numerical control would block the
system. In that case eliminate the residual pressure,
(
Ref.par.9.1
), and
proceed as described in paragraph
7.2.3.1 FIRST FILLING UP
WARNING
During the filling operations, always
disconnect the system from the
compressed air by acting on the manual
sliding valve and on the multiplier supply
pressure reducer by turning it fully
counterclockwise.
When filling the tank, never exceed the
"maximum"(B) level.
NOTICE
Use the same oil in case of subsequent
fillings, otherwise make sure to remove all
traces of the lubricant previously used via
the oil drain cock.
Only then fill the tank with the new oil and
operate the equipment.
DropsA declines all responsibility for the
incorrect operation of the equipment.
Recommended lubricants: MaXtreme
Oil
ANALOGUE MINIMUM
LEVEL ALARM CONNECTION
OIL DRAIN
(15)
(A) OIL LEVEL MIN
(
B) MAX OIL LEVEL
OIL FILLING