20
Close the oil outlet. Fill the unit with new lubricant (approx. 2 lt - 0, 44 gallons- as described in
5.3.1
.)
Put the equipment back into operation (
see Chap. 8. Instruction for use
)
WARNING
Before any maintenance operation, make
sure that the pneumatic supply is
disconnected.
10. DISPOSAL
During maintenance on the machine, or in the event of its demoliton, do not dispose of contaminated parts into the
environment. See local regulations for their correct disposal. Upon dmolition of the machine, the identification label
and any other document must be destroyed.
11. ORDER INFORMATION
Accessories
Part number
Description
3155187
Solenoid valve for aerosol control
0295188
Air multiplier kit
0295189
On/Off solenoid valve kit for high-pressure circuit
0295272
On/Off solenoid valve kit for low-pressure circuit
Consumable Products
Part number
Description
3226692
Maxtreme
- Oil 22 Lt
3226693
Maxtreme
- Oil 206 Lt
3226694
Maxtreme
- Oil 980 Lt
Part number
Description
3135263
Maxtreme
-1 with minimum level, single nozzle (HP circuit deactivate)
3135264
Maxtreme
- with minimum double-level nozzle
Spares parts
Part number
Description
0020685
Pressure adjustment valve 0~10 Bar
3292142
0-25 Bar pressure gauge
3155312
Safety valve
3089043
Aircheck valve