Contact the sales office Dropsa for other primary and the inverter supply voltages.

 

6. UNPACKING AND INSTALLATION 

 

6.1  UNPACKING 

Once the suitable location for installation has been identified, open the package and remove the pump. Check that it was not 

damaged during transport or storage. The packaging material does not require special disposal precautions as it is not in any 

way dangerous or polluting. Refer to the local regulations for disposal. 

 

6.2  INSTALLATION 

Pump assembly operations are not required.. The pump is fixed on a metal pallet that permits safe handling with a transpallet or 

fork lift truck. The pallet was designed to be installed in the plant. It has four 



14 

mm holes suitable for fixing to the floor. 

Suitable space must be provided (as shown in the installation diagram) to prevent abnormal positions or the possibility of 

impacts. Then, as described above, the pump must be connected hydraulically to the machine and then the connection to the 

control panel must be made. 

 

7. INSTRUCTIONS FOR USE 

 

7.1 STARTING THE PUMP 

Before using the MINI SUMO pump, a few preliminary checks must be performed: 

 

Check the integrity of the power supply cable and the unit prior to use. 

 

If there is damage to the power supply cable or the unit, do not start operations! 

 

Replace the damaged power supply cable with a new one. 

 

The unit may only be opened and repaired by specialised personnel. 

 

In order to prevent the danger of electrocution due to direct or indirect contact with live parts, the electric power supply line 

must be suitably protected by a specific differential magnetothermic switch,  according to regulations and with rated 

breaking capacity at list equal to prospective fault current at installation point. 

 

It is prohibited to use the pump if submersed in fluids or in a particularly aggressive or explosive/inflammable environment if 

not previously prepared for that purpose by the supplier. 

 

Use safety gloves or glasses as specified in the safety sheet for the lubricating oil 

 

DO NOT use aggressive lubricants with NBR gaskets. In the case of doubt, contact the Dropsa SpA technical office to receive a 

detailed card about the recommended oils. 

 

Do not ignore the hazards to health and comply with the health regulations.

 

 

 

 

 

 

 

 

Check the integrity of the pump. 

 

Check that the pump is at the operating temperature and that there are no air bubbles in the pipes. 

 

Check that the electric connection was carried out correctly. 

 

Once the pump has started, check that the direction of rotation of the electric motor is as indicated by the arrow on the 

motor's protective casing; if it rotates backward; reconnect it as shown in the wiring diagram provided with the motor. 

 

7.2 INSTRUCTIONS FOR USE 

1)

 

Press the start button on the machine to which the pump is connected or start it; 

2)

 

Check the that the pump starts; 

3)

 

To change the pressure value, turn the adjustment screw (see Chap. 5). Turn it clockwise to increase the pressure or counter 

clockwise to decrease it; 

4)

 

Check that the machine lubrication is suitable (if there are doubts about correct operation, the Dropsa SpA technical office 

can be contacted to request the inspection procedure). 

 

 

 

 

 

 

 

 

ATTENTION

:

 All components must be ground connected. This applies both to electric components as well as to control 

devices. For this purpose, make sure that the ground wire is directly connected. For safety reasons, the ground conductor 

must be approx. 100 mm longer than the phase conductors. If the cable is accidentally disconnected, the ground terminal 

must be the last to be disconnected.

 

 

Summary of Contents for 2487000

Page 1: ...URES 5 MACHINE COMPONENTS 6 UNPACKING AND INSTALLATION 7 INSTRUCTIONS FOR USE 8 PROBLEMS AND SOLUTIONS 9 MAINTENANCE PROCEDURES 10 DISPOSAL 11 ORDER INFORMATION 12 DIMENSIONS 13 HANDLING AND TRANSPORT...

Page 2: ...by selecting from a set of components that are perfectly compatible with each other and easily assembled it is possible to vary the pressure the quantity of the delivered lubricant the type of lubrica...

Page 3: ...50 60Hz 1340 rpm 440 480Y 255 280 60Hz 1610 rpm 110 V 50 Hz 1370 rpm 230 V 50 Hz 1370 rpm 24 V CC 2800 rpm 1 Rated motor power 0 18 Kw Motor degree of protection IP 55 Minimum and maximum level Laser...

Page 4: ...oil pump with hydraulic change over Dual line 0 380 BAR Hydraulic diagram for standard pump with single grease outlet Min laser level NO o NC Max visible level G BSP Lubricant loading Min laser level...

Page 5: ...AR 0 18 kw 4p Invertitore elettropneumatico Electropneumatic switch G BSP Caricamento lubrificante Lubricant loading Minimo livello laser Min laser level NO o NC Hydraulic diagram for grease pump with...

Page 6: ...d seal This solution guarantees optimal system sealing at high operating pressures max pressure of 380 bar The pumping elements are mounted on the pump casing without the need to disconnect the line p...

Page 7: ...y a luminous signal on the electric panel it also controls any automatic tank filling pump command 5 1 7 SPATULA FOR GREASE AND OIL STANDARD VERSION Two tanks have been foreseen with capacities of 10...

Page 8: ...pressures the inversion phase is facilitated by a balancing system sealing gaskets that can support high pressure levels by means of a pressurised chamber optimising the inverter function Two single a...

Page 9: ...equal to prospective fault current at installation point It is prohibited to use the pump if submersed in fluids or in a particularly aggressive or explosive inflammable environment if not previously...

Page 10: ...ally 2 immerse the sensor in the lubricant down to half of its length 3 remove the sensor from the lubricant until it skims the surface of the lubricant 4 at this point there can be two possible types...

Page 11: ...elow the table with the calibration parameters of ultrasound probe for 10 and 30 kg reservoirs 8 PROBLEMS AND SOLUTIONS Figure 6 LASER PROBE CALIBRATION 10 kg Reservoir 30 kg Reservoir Pos Level Outpu...

Page 12: ...ree motor phases See above Disconnect the pump delivery pipe and bleed the lubricant until the air bubbles have been eliminated The pump does not pressurise There may be dirt on the pumping element ch...

Page 13: ...ts but contact the DROPSA S p A technical office 10 DISPOSAL During machine maintenance or if it is demolished do not dispose of the polluting parts in an improper manner Refer to the local regulation...

Page 14: ...DARD OIL VERSION With Floating Reed 0295151 For 10 Kg 0295150 For 30 Kg Variants Min max laser level Kit 24V cc Out 4 20mA 2 NO 4 thresholds 0295130 2 Pump Ultrasound Level Kit 10 Kg 0295140 3 Pump Ul...

Page 15: ...tion Variant Code Motors 3 Ph 0 18 Kw 230 400Y 50Hz 1350 rpm 277 480Y 60Hz 1620 rpm 0297002 UL CSA 3 Ph 0 18 Kw 330 575Y 60Hz 1690 rpm 3301574 UL CSA 3 Ph 0 18 Kw 208 360Y 60Hz 1610 rpm 230 400Y 60Hz...

Page 16: ...16 12 DIMENSIONS 10 Kg 30 Kg A 344 5 533 5 B 803 994 C 688 879 D 577 768 Z 275 325 X 265 265 Y 175 175...

Page 17: ...and making sure that no one can reconnect it during the operation All the installed equipment electric and electronic tanks and basic structures must be connected to the ground line Inflammability The...

Page 18: ...Compliance with the essential safety requirements Machine Directive EC 06 42 The risks that were not completely eliminated but considered acceptable are specified below Electrocution this can only occ...

Reviews: