background image

18 

A comparison table is provided between the classification of NLGI lubricants (National 

Lubricating Grease Institute) and the ASTM classification (American Society for Testing and 

Materials) for greases for the values that concern the pump. 

For further information about the technical specifications and the safety measures to adopt, 

refer to the product safety sheet (Directive 93/112/EEC) relative to the type of lubricant 

selected and supplied by the manufacturer. 

 

15. GUIDELINES FOR USE 

 

Compliance with the essential safety requirements and the provisions specified in the machine directive was checked by filling 

out prepared check lists that are contained in the technical file. 

Two types of lists were used: 

 

 

Risk assessment (UNI EN ISO 14121-1). 

 

Compliance with the essential safety requirements Machine Directive –EC 06/42). 

 

The risks that were not completely eliminated, but considered acceptable, are specified below: 

 

 

Electrocution: this can only occur in the case of serious user incompetence. 

 

Use of unsuitable lubricant: the types of fluids that are not compatible with correct pump operation are listed below. * 

 

Contact with harmful fluids. 

 

 

FLUIDS THAT ARE NOT PERMITTED 

FLUIDS 

RISKS 

Lubricants with abrasive additives 

wear of the components inside the pump 

Lubricants with silicone additives 

Pump seizure 

Petrol – solvents – inflammable liquids 

Fire – explosion – damage to the gaskets 

Corrosive products  

Pump corrosion - damage to people 

Water 

Pump oxidation 

Food substances 

They would be contaminated 

* For more detailed information regarding product compatibility with particular fluids, contact the Dropsa S.p.A. technical office

 

 

 

 

 

GREASES

 

NLGI 

ASTM 

000 

445 – 475 

00 

400 – 430 

355 – 385 

310 – 340 

265 – 295 

 

Summary of Contents for 2487000

Page 1: ...URES 5 MACHINE COMPONENTS 6 UNPACKING AND INSTALLATION 7 INSTRUCTIONS FOR USE 8 PROBLEMS AND SOLUTIONS 9 MAINTENANCE PROCEDURES 10 DISPOSAL 11 ORDER INFORMATION 12 DIMENSIONS 13 HANDLING AND TRANSPORT...

Page 2: ...by selecting from a set of components that are perfectly compatible with each other and easily assembled it is possible to vary the pressure the quantity of the delivered lubricant the type of lubrica...

Page 3: ...50 60Hz 1340 rpm 440 480Y 255 280 60Hz 1610 rpm 110 V 50 Hz 1370 rpm 230 V 50 Hz 1370 rpm 24 V CC 2800 rpm 1 Rated motor power 0 18 Kw Motor degree of protection IP 55 Minimum and maximum level Laser...

Page 4: ...oil pump with hydraulic change over Dual line 0 380 BAR Hydraulic diagram for standard pump with single grease outlet Min laser level NO o NC Max visible level G BSP Lubricant loading Min laser level...

Page 5: ...AR 0 18 kw 4p Invertitore elettropneumatico Electropneumatic switch G BSP Caricamento lubrificante Lubricant loading Minimo livello laser Min laser level NO o NC Hydraulic diagram for grease pump with...

Page 6: ...d seal This solution guarantees optimal system sealing at high operating pressures max pressure of 380 bar The pumping elements are mounted on the pump casing without the need to disconnect the line p...

Page 7: ...y a luminous signal on the electric panel it also controls any automatic tank filling pump command 5 1 7 SPATULA FOR GREASE AND OIL STANDARD VERSION Two tanks have been foreseen with capacities of 10...

Page 8: ...pressures the inversion phase is facilitated by a balancing system sealing gaskets that can support high pressure levels by means of a pressurised chamber optimising the inverter function Two single a...

Page 9: ...equal to prospective fault current at installation point It is prohibited to use the pump if submersed in fluids or in a particularly aggressive or explosive inflammable environment if not previously...

Page 10: ...ally 2 immerse the sensor in the lubricant down to half of its length 3 remove the sensor from the lubricant until it skims the surface of the lubricant 4 at this point there can be two possible types...

Page 11: ...elow the table with the calibration parameters of ultrasound probe for 10 and 30 kg reservoirs 8 PROBLEMS AND SOLUTIONS Figure 6 LASER PROBE CALIBRATION 10 kg Reservoir 30 kg Reservoir Pos Level Outpu...

Page 12: ...ree motor phases See above Disconnect the pump delivery pipe and bleed the lubricant until the air bubbles have been eliminated The pump does not pressurise There may be dirt on the pumping element ch...

Page 13: ...ts but contact the DROPSA S p A technical office 10 DISPOSAL During machine maintenance or if it is demolished do not dispose of the polluting parts in an improper manner Refer to the local regulation...

Page 14: ...DARD OIL VERSION With Floating Reed 0295151 For 10 Kg 0295150 For 30 Kg Variants Min max laser level Kit 24V cc Out 4 20mA 2 NO 4 thresholds 0295130 2 Pump Ultrasound Level Kit 10 Kg 0295140 3 Pump Ul...

Page 15: ...tion Variant Code Motors 3 Ph 0 18 Kw 230 400Y 50Hz 1350 rpm 277 480Y 60Hz 1620 rpm 0297002 UL CSA 3 Ph 0 18 Kw 330 575Y 60Hz 1690 rpm 3301574 UL CSA 3 Ph 0 18 Kw 208 360Y 60Hz 1610 rpm 230 400Y 60Hz...

Page 16: ...16 12 DIMENSIONS 10 Kg 30 Kg A 344 5 533 5 B 803 994 C 688 879 D 577 768 Z 275 325 X 265 265 Y 175 175...

Page 17: ...and making sure that no one can reconnect it during the operation All the installed equipment electric and electronic tanks and basic structures must be connected to the ground line Inflammability The...

Page 18: ...Compliance with the essential safety requirements Machine Directive EC 06 42 The risks that were not completely eliminated but considered acceptable are specified below Electrocution this can only occ...