background image

11 

 

These are amplified sensors AC.  In this version, the standard characteristics of the sensors 

include protection against permanent load short circuit, and protection against the peaks 

produced when the inductive loads are disconnected.

 

 

 

 

7.2.3  Procedure for calibrating the laser probe 24V cc Out 4÷20mA/2 NO (4 thresholds) 

The laser probe has an on-board viewing and programming display. It is possible to work in analogue (with a 4 to 20 mA signal) 

or digital (two outputs and four intervention thresholds) mode. 

The table with the laser probe calibration parameters is shown below. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 
7.2.4 CALIBRATION THRESHOLDS OF THE ULTRASOUND PROBE (optional) 

The green led indicates the probe is powered. 

Yellow LED indicates the operating mode of reading. 

Below the table with the calibration parameters of ultrasound probe, for 10 and 30 kg reservoirs.

  

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8. PROBLEMS AND SOLUTIONS 

 

 

Figure 6 

L

ASER PROBE CALIBRATION

 

 

 

 

 

10 kg Reservoir 

30 kg Reservoir 

Pos. 

Level 

Output signal 

Set-up  Height X 

[mm] 

Grease 

quantity 

[kg] 

Height X 

[mm] 

Grease 

quantity 

[kg] 

Absolute 

maximum level 

 

 

OUT 2= Fno 

 

nsP2 

220 

11 

220 

23 

Minimum level 

fsP2 

300 

490 

Maximum level 

 

 

OUT 1= Fno 

nsP1 

250 

250 

21 

Absolute 

minimum level 

fsP1 

330 

520 

 

SENSITIVITY 

ADJUSTMENT 

LED 

CABL

 

SENSOR  (BACK VIEW) 

NOTE

To change calibration thresholds of laser and ultrasound probes contact DROPSA staff  

 

 

Figure 7 

ULTRASOUND PROBE CALIBRATION

 

Pos. 

 

 

Reservoir 10 kg 

Reservoir 30 kg 

 

Level

 

Output 

signal

 

Height X 

[mm]

 

Grease 

quantity [kg] 

Height X 

[mm] 

Grease 

quantity [kg] 

Absolute 

maximum 

level

 

1 threshold 

110 

10 

110 

25 

Absolute 

minimum 

level

 

2 threshold 

270 

490 

 

              

 

ATTENTION

The machine may only be opened and repaired by authorised Dropsa personnel.

 

  

 

Summary of Contents for 2487000

Page 1: ...URES 5 MACHINE COMPONENTS 6 UNPACKING AND INSTALLATION 7 INSTRUCTIONS FOR USE 8 PROBLEMS AND SOLUTIONS 9 MAINTENANCE PROCEDURES 10 DISPOSAL 11 ORDER INFORMATION 12 DIMENSIONS 13 HANDLING AND TRANSPORT...

Page 2: ...by selecting from a set of components that are perfectly compatible with each other and easily assembled it is possible to vary the pressure the quantity of the delivered lubricant the type of lubrica...

Page 3: ...50 60Hz 1340 rpm 440 480Y 255 280 60Hz 1610 rpm 110 V 50 Hz 1370 rpm 230 V 50 Hz 1370 rpm 24 V CC 2800 rpm 1 Rated motor power 0 18 Kw Motor degree of protection IP 55 Minimum and maximum level Laser...

Page 4: ...oil pump with hydraulic change over Dual line 0 380 BAR Hydraulic diagram for standard pump with single grease outlet Min laser level NO o NC Max visible level G BSP Lubricant loading Min laser level...

Page 5: ...AR 0 18 kw 4p Invertitore elettropneumatico Electropneumatic switch G BSP Caricamento lubrificante Lubricant loading Minimo livello laser Min laser level NO o NC Hydraulic diagram for grease pump with...

Page 6: ...d seal This solution guarantees optimal system sealing at high operating pressures max pressure of 380 bar The pumping elements are mounted on the pump casing without the need to disconnect the line p...

Page 7: ...y a luminous signal on the electric panel it also controls any automatic tank filling pump command 5 1 7 SPATULA FOR GREASE AND OIL STANDARD VERSION Two tanks have been foreseen with capacities of 10...

Page 8: ...pressures the inversion phase is facilitated by a balancing system sealing gaskets that can support high pressure levels by means of a pressurised chamber optimising the inverter function Two single a...

Page 9: ...equal to prospective fault current at installation point It is prohibited to use the pump if submersed in fluids or in a particularly aggressive or explosive inflammable environment if not previously...

Page 10: ...ally 2 immerse the sensor in the lubricant down to half of its length 3 remove the sensor from the lubricant until it skims the surface of the lubricant 4 at this point there can be two possible types...

Page 11: ...elow the table with the calibration parameters of ultrasound probe for 10 and 30 kg reservoirs 8 PROBLEMS AND SOLUTIONS Figure 6 LASER PROBE CALIBRATION 10 kg Reservoir 30 kg Reservoir Pos Level Outpu...

Page 12: ...ree motor phases See above Disconnect the pump delivery pipe and bleed the lubricant until the air bubbles have been eliminated The pump does not pressurise There may be dirt on the pumping element ch...

Page 13: ...ts but contact the DROPSA S p A technical office 10 DISPOSAL During machine maintenance or if it is demolished do not dispose of the polluting parts in an improper manner Refer to the local regulation...

Page 14: ...DARD OIL VERSION With Floating Reed 0295151 For 10 Kg 0295150 For 30 Kg Variants Min max laser level Kit 24V cc Out 4 20mA 2 NO 4 thresholds 0295130 2 Pump Ultrasound Level Kit 10 Kg 0295140 3 Pump Ul...

Page 15: ...tion Variant Code Motors 3 Ph 0 18 Kw 230 400Y 50Hz 1350 rpm 277 480Y 60Hz 1620 rpm 0297002 UL CSA 3 Ph 0 18 Kw 330 575Y 60Hz 1690 rpm 3301574 UL CSA 3 Ph 0 18 Kw 208 360Y 60Hz 1610 rpm 230 400Y 60Hz...

Page 16: ...16 12 DIMENSIONS 10 Kg 30 Kg A 344 5 533 5 B 803 994 C 688 879 D 577 768 Z 275 325 X 265 265 Y 175 175...

Page 17: ...and making sure that no one can reconnect it during the operation All the installed equipment electric and electronic tanks and basic structures must be connected to the ground line Inflammability The...

Page 18: ...Compliance with the essential safety requirements Machine Directive EC 06 42 The risks that were not completely eliminated but considered acceptable are specified below Electrocution this can only occ...