background image

drive.web automation

Set up your computer - Get

 

savvy

 

With  free 

drive.web

 

savvy

  software,  easily  program  and 

monitor your

 

smarty

, perform data trending, and create 

distributed control systems. 

Go  to 

www.driveweb.com

  and  click  on 

Get  savvy

,  or 

contact us to get the latest version of  

savvy.

 

smarty 

USB - Plug and Play

 

Plug-and-play  access  to 

smarty

 

and

  its  local  Ethernet 

network. 

smarty 

Ethernet Networking & Programming

 

Assigning an invalid or duplicate IP address will cause serious 

network malfunctions!  

Find useful networking information. Under the 

Help

 menu 

click on

 

Getting Started with savvy

 section.  

smarty

s  are  shipped  with  an  IP  address,  10.189.x.x, 

derived  from  the  serial  number.  The  six-octet  serial 

number  always  starts  with  0-4-bb-x.  The  last  two  octets 

are used to assign the as-shipped IP address; Example, if  

the serial number is 0-4-bb-00-1a-2b, 1a is converted from 

hexadecimal  to  decimal,  26.  2b,  similarly,  is  43,  decimal. 

The as-shipped address is 10.189.26.43. 

Use 

Category 5e

 cable or better, with 8P8C/RJ-45 connectors 

for each 

drive.web 

 device and the host computer. 

For  systems  with  more  than  one 

drive.web

  device,  use  an 

Ethernet switch for all 

drive.web

 devices and computer. 

Get started with 

savvy

 

We  strongly  recommend  attending  our  free  online 

training seminars. See page 12.

 

We  strongly  recommend  you  read  the 

User  Manual

 

and 

Getting Started Guides

 under the 

Help

 menu.    

Use 

Create  Phantom

  in  the 

Directory

  menu  to 

explore 

drive.web

 

products  and  options,  design, 

and  configure  offline. 

Export  Data

  to  save  your 

work. 

Import Data

 into  phantoms to work offline.  

savvy

 Window Title Bar

 

indicates the current view. 

Status  Bar

,

 

above  the  viewing  area,  provides 

Navigation 

Arrows 

and object and location data. 

savvy

 views are hierarchical with the 

Device Directory 

View

 at top. Use the 

Navigation Arrows

 to go up, back, 

or forward. Window menus change as you navigate.  

Hover  cursor  over  active  object

, device, function block, 

connection, or parameter icon to view object information 

in the 

Status Bar

 and reveal a 

Hover Button

Click  a  Hover  Button  or  right-click

  an  active  object  to 

access a 

Contextual Menu

. See below. 

savvy

 

functions  are  limited

  by  password-protected 

capability level. See 

File > Capability...

smarty

 

HG503894Beta13

 

 

www.driveweb.com

              

              

Page 

#

/12

8

Summary of Contents for smarty dw240

Page 1: ...kaging contain recyclable materials This device is designed to comply with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation This Class A digital apparatus is designed to comply with Canadian ICES 003 Cet appa...

Page 2: ...ROCUREMENT OF SUBSTITUTE GOODS OR SERVICES LOSS OF USE DATA OR PROFITS OR BUSINESS INTERRUPTION HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY WHETHER IN CONTRACT STRICT LIABILITY OR TORT INCLUDING NEGLIGENCE OR OTHERWISE ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE Product Identification smarty Cassette Models smarty is a programmable device ...

Page 3: ...coder input 5 5VDC max 0 5VDC min 0 3VDC minimum differential Voltage Up to 1MHz ModbusRTU serial port is brought out to terminals instead of the jack in C2 smarty C4 Carrier 4 Ratings and Features adds to C3 Two 4 20mA current inputs Also 0 20mA 20 4mA and 20 0mA 100Ω input impedance Maximum input is 25mA 2 5VDC Six frequency event digital inputs 30Vmax 100kHz Replaces FT on C3 Seven frequency st...

Page 4: ...n and blinks for activity 100BaseTX Green LED when 100BaseTX connection is made Carriers C1 and C2 Terminals and Dimensions smarty HG503894Beta13 www driveweb com Page 12 4 use in order only ctual size hite beyond 02441 for ol Gray 99 00mm Ref ue Drawing Title Drawn by Property of smarty front label art Ian Bardwell Jones Bardac Corp drive web smarty 100 1 2 PoE lOlOl r use in order only actual si...

Page 5: ...V A B Carrier C3 Terminals and Dimensions Realtime Clock Battery CR2032 Realtime clock will be maintained for approximately 24hrs with no backup battery 4P4C XIO Port 8P8C CANopen Serial Port Width Overall 140mm 5 51 Height Overall 87mm 3 43 DINrail release clip Overall Height Back Panel to Front Panel 75mm 2 95 DI Digital Input DO Digital Output AO Analog Output AI Analog Input 1A Encoder 1 Chann...

Page 6: ...5 TO7 0V 0V 0V 0V 0V 0V 0V 24V 0V 24V 0V A B 0V 1A 1A 1B 1B 0V 2A 2A 2B 2B Carrier C4 Terminals and Dimensions 4P4C XIO Port 8P8C CANopen Serial Port Width Overall 210mm 8 27 Height Overall 87mm 3 43 DI Digital Input DO Digital Output AO Analog Output AI Analog Input CI Current Input 1A Encoder 1 Channel A 1B Encoder 1 Channel B 1Z Encoder 1 Marker 5V 5VDC Power Output FI Frequency Input TPW Power...

Page 7: ...o the unit depending on the installation Signal Wiring Notes Use twisted pair wiring for encoder and serial differential signals Outside metal enclosure use shielded cable with individually shielded twisted pairs such as Belden 8163 Ground shield at one end with a 360 ground clamp where cable enters quiet metal enclosure Separate wiring from AC power cables or RF noise sources smarty I O Functions...

Page 8: ...s for each drive web device and the host computer For systems with more than one drive web device use an Ethernet switch for all drive web devices and computer Get started with savvy We strongly recommend attending our free online training seminars See page 12 We strongly recommend you read the User Manual and Getting Started Guides under the Help menu Use Create Phantom in the Directory menu to e...

Page 9: ... Import Export Device Data Load save configuration data to from this smarty only Unlock Lock Set Password Choose Restrict Modification to allow viewing the configuration or Restrict All Access Click the smarty icon to view the device configuration Function Block Engine Window FBE Menu Standard savvy no SFD Add function blocks in the order to be processed Processing order is left to right top to bo...

Page 10: ...n blocks and connections is at the left of the Signal Flow Diagram showing program execution order from top down Change execution order by dragging function blocks up or down the list In this picture ENC1 Speed function block is moved so that it is processed after ENC Phase Lock savvyPanel Operator Station Computers Apple mobile digital devices iPad iPhone and iPod Touch are operator touch station...

Page 11: ... in Java based savvyPanel Appears as graphic tile in iOS Function blocks enable savvyPanel actions Alarm Annunciator Provides a system wide alarm annunciation when active Touch to view page 255 Presence Monitor Indicates the presence of a tagged savvyPanel application viewing a particular page Latch and SR Latch For lighted start stop pushbuttons Setpoint Monitor Adjust meter and setter range Dual...

Page 12: ...t write or force parameters that are read only or have incoming drive web connections Click the Comms Server icon in the FBE or SFD view dwOption 04 ModbusTCP IP slave server Supported Modbus Function Codes 1 thru 6 15 and 16 Supports up to five simultaneous clients masters dwOption 25 EIP PCCC Server Supports PLC5 Typed Write and Typed Read commands See Appendix B of the savvy User Manual for inf...

Reviews: