background image

drive.web automation

Warning! 

You are entirely responsible for the configuration or use of  any 

drive.web

 

product. By configuring 

or using these products you agree to indemnify and hold harmless Bardac Corporation, its employees, directors, 

officers, distributors, and resellers against the consequences of  your configuration or use of  the products. 

Warning! 

Information in this manual is subject to change without notice. You are responsible for verifying the 

proper operation of  your 

smarty

. Special care must be taken after loading new firmware or installing new options.

Warning! 

Avoid permanent damage to your 

smarty

, never exceed any 

min

 or 

max

 values.  Do not connect 

any 

smarty

 terminal to mains circuits. See page 5 for IO ratings.

 

lwIP is incorporated into 

smarty

 firmware. lwIP Copyright (c) 2001-2004 Swedish Institute of  Computer Science. All rights reserved. 

Redistribution and use in source and binary forms, with or without modification, are permitted provided that the following conditions are met: 
1. Redistributions of  source code must retain the above copyright notice, this list of  conditions and the following disclaimer. 

2. Redistributions in binary form must reproduce the above copyright notice, this list of  conditions and the following disclaimer in the documentation and/or 
other materials provided with the distribution. 

3. The name of  the author may not be used to endorse or promote products derived from this software without specific prior written permission. 
THIS  SOFTWARE  IS  PROVIDED  BY  THE  AUTHOR  “AS  IS''  AND  ANY  EXPRESS  OR  IMPLIED  WARRANTIES,  INCLUDING,  BUT  NOT 

LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE DISCLAIMED. IN 
NO EVENT SHALL THE AUTHOR BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL 

DAMAGES  (INCLUDING,  BUT  NOT  LIMITED  TO,  PROCUREMENT  OF  SUBSTITUTE  GOODS  OR  SERVICES;  LOSS  OF  USE,  DATA,  OR 
PROFITS; OR BUSINESS INTERRUPTION) HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT 

LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN 
IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE. 

Product Identification - 

smarty

 

Cassette Models

smarty  

is  a  programmable  device  using 

drive.web

  distributed 

control  over  Ethernet  for  industrial  process  automation.  To 

program  and  use 

smarty

  you  must  get  the 

savvy

  software 

tools from 

www.driveweb.com

. See pages 6-9.

 

Find 

smarty

  firmware  version.  Use 

savvy

Get  Detailed 

Info

 from 

smarty

 contextual menu. Page 6.  

dw240

 Universal automation controller. 

dw241

 Basic automation controller for carrier 

C1

 only. 

dw244

 for 

P2

  industrial vector drive. 

dw248

 for 

E3

 open-loop vector drive. 

dw249

 Universal automation controller for 

CANopen

 server devices. 

These 

smarty

 cassette modules install into terminal block carriers.

 

Warning!

  Avoid  permanent  damage  to 

smarty

.  Disconnect  all 

power sources prior to inserting or removing the cassette.

 

 

Product Identification - Part Number Extensions

Model number

 

dw24x 

is appended with a two or six character extension. 

Standard Builds 

A, B, C,

 and 

D

 - Software Options 

 

A

=04 and 26, 

B

 adds 05 and 25, 

C

 adds 06 and 39, 

D

 adds 10 and 29. 

04 ModbusTCP/IP

 - Slave/server.

 

See page 12. 

05 Process Control

 - Recommended for most applications. 

06 Winder Control

 - Diameter Calc., Taper Tension, Torque Comp. 

10 Math

 - With advanced math functions.

 

 

25 EIP/PCCC

 - Slave/server. See page 12. 

26 

savvyPanel

 - Operator station interface. See pages 8, 9. 

29 Solar 

-

 

Calculates sun position azimuth and zenith. 

39 Precision Motion 

-

 

With event, length, position, shaft-lock,  

indexing, motion control, cam profile, and more. Page 12. 

smarty

 

HG503894Beta13

 

 

www.driveweb.com

              

              

Page 

#

/12

2

Typical Example; 

dw240-DM-C4CD

Standard Build, see below.

ModbusRTU Type, see page 12.

Carrier, page 3.

Terminal Type; C=Cage-

Spring, S=Screw-Clamp, 
P=Pluggable Screw-Clamp

Mounting Type; D=DINrail, 

F=Foot, A=Spacer, 4=NEMA4X

Summary of Contents for smarty dw240

Page 1: ...kaging contain recyclable materials This device is designed to comply with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation This Class A digital apparatus is designed to comply with Canadian ICES 003 Cet appa...

Page 2: ...ROCUREMENT OF SUBSTITUTE GOODS OR SERVICES LOSS OF USE DATA OR PROFITS OR BUSINESS INTERRUPTION HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY WHETHER IN CONTRACT STRICT LIABILITY OR TORT INCLUDING NEGLIGENCE OR OTHERWISE ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE Product Identification smarty Cassette Models smarty is a programmable device ...

Page 3: ...coder input 5 5VDC max 0 5VDC min 0 3VDC minimum differential Voltage Up to 1MHz ModbusRTU serial port is brought out to terminals instead of the jack in C2 smarty C4 Carrier 4 Ratings and Features adds to C3 Two 4 20mA current inputs Also 0 20mA 20 4mA and 20 0mA 100Ω input impedance Maximum input is 25mA 2 5VDC Six frequency event digital inputs 30Vmax 100kHz Replaces FT on C3 Seven frequency st...

Page 4: ...n and blinks for activity 100BaseTX Green LED when 100BaseTX connection is made Carriers C1 and C2 Terminals and Dimensions smarty HG503894Beta13 www driveweb com Page 12 4 use in order only ctual size hite beyond 02441 for ol Gray 99 00mm Ref ue Drawing Title Drawn by Property of smarty front label art Ian Bardwell Jones Bardac Corp drive web smarty 100 1 2 PoE lOlOl r use in order only actual si...

Page 5: ...V A B Carrier C3 Terminals and Dimensions Realtime Clock Battery CR2032 Realtime clock will be maintained for approximately 24hrs with no backup battery 4P4C XIO Port 8P8C CANopen Serial Port Width Overall 140mm 5 51 Height Overall 87mm 3 43 DINrail release clip Overall Height Back Panel to Front Panel 75mm 2 95 DI Digital Input DO Digital Output AO Analog Output AI Analog Input 1A Encoder 1 Chann...

Page 6: ...5 TO7 0V 0V 0V 0V 0V 0V 0V 24V 0V 24V 0V A B 0V 1A 1A 1B 1B 0V 2A 2A 2B 2B Carrier C4 Terminals and Dimensions 4P4C XIO Port 8P8C CANopen Serial Port Width Overall 210mm 8 27 Height Overall 87mm 3 43 DI Digital Input DO Digital Output AO Analog Output AI Analog Input CI Current Input 1A Encoder 1 Channel A 1B Encoder 1 Channel B 1Z Encoder 1 Marker 5V 5VDC Power Output FI Frequency Input TPW Power...

Page 7: ...o the unit depending on the installation Signal Wiring Notes Use twisted pair wiring for encoder and serial differential signals Outside metal enclosure use shielded cable with individually shielded twisted pairs such as Belden 8163 Ground shield at one end with a 360 ground clamp where cable enters quiet metal enclosure Separate wiring from AC power cables or RF noise sources smarty I O Functions...

Page 8: ...s for each drive web device and the host computer For systems with more than one drive web device use an Ethernet switch for all drive web devices and computer Get started with savvy We strongly recommend attending our free online training seminars See page 12 We strongly recommend you read the User Manual and Getting Started Guides under the Help menu Use Create Phantom in the Directory menu to e...

Page 9: ... Import Export Device Data Load save configuration data to from this smarty only Unlock Lock Set Password Choose Restrict Modification to allow viewing the configuration or Restrict All Access Click the smarty icon to view the device configuration Function Block Engine Window FBE Menu Standard savvy no SFD Add function blocks in the order to be processed Processing order is left to right top to bo...

Page 10: ...n blocks and connections is at the left of the Signal Flow Diagram showing program execution order from top down Change execution order by dragging function blocks up or down the list In this picture ENC1 Speed function block is moved so that it is processed after ENC Phase Lock savvyPanel Operator Station Computers Apple mobile digital devices iPad iPhone and iPod Touch are operator touch station...

Page 11: ... in Java based savvyPanel Appears as graphic tile in iOS Function blocks enable savvyPanel actions Alarm Annunciator Provides a system wide alarm annunciation when active Touch to view page 255 Presence Monitor Indicates the presence of a tagged savvyPanel application viewing a particular page Latch and SR Latch For lighted start stop pushbuttons Setpoint Monitor Adjust meter and setter range Dual...

Page 12: ...t write or force parameters that are read only or have incoming drive web connections Click the Comms Server icon in the FBE or SFD view dwOption 04 ModbusTCP IP slave server Supported Modbus Function Codes 1 thru 6 15 and 16 Supports up to five simultaneous clients masters dwOption 25 EIP PCCC Server Supports PLC5 Typed Write and Typed Read commands See Appendix B of the savvy User Manual for inf...

Reviews: