smarty

 

Precision Motion Functions, Connections

Special parameter and connection types from I/O function blocks. 

Connections  can  also  be  made  over  Ethernet  to  other 

drive.web

 devices. 

Floating Point 

- IEEE-754 Binary32 values for frequency, speed, 

position,  and  other  wide  value  ranges.  Floating  point  math 

function blocks are available for additional processing. 

Event 

- Events are associated with exact count values. Maximum 

event  frequency  is  (1/(FBE  Timebase  seconds))  Hz.  Only  the 

first event is processed per FBE cycle. 

Count 

- Position applications including shaft-lock, motion control, 

and  registration.  64-bit  internal  values  with  precision  timing 

data.

 

smarty

 

Comms Interfaces-Modbus & EIP/PCCC

Warning! 

Use of  

smarty

 

comms interfaces, ModbusTCP, 

ModbusRTU, and EIP/PCCC, may cause motors and 

machinery to energize with high Voltages, or start, or 

operate in an unexpected, dangerous, or lethal way.

 

For Modbus specs go to 

http://modbus.org/specs.php

 

smarty

 

Comms Server 

dwOption-04 and -25 

Note!

  You  cannot  write  or  force  parameters  that  are  read-

only or have incoming 

drive.web

 connections. 

Click the 

Comms Server

 icon in the 

FBE

 or 

SFD

 view. 

dwOption-04

 ModbusTCP/IP slave/server

Supported Modbus Function Codes; 1 thru 6, 15, and 16. 
Supports up to 

five simultaneous clients/masters

.

  

dwOption-25 

EIP/PCCC Server

Supports PLC5 Typed-Write and Typed-Read commands. 
See Appendix B of  the

 

savvy

 User Manual for information 

and 

drive.web

 parameter IDs mapping to PLC5. 

Supports up to 

two simultaneous clients

.

 

ModbusRTU Type  

(not available in C1)

M

=Master-Client, 

S

=Slave-Server, 

X

=None-e.g. 

dw241

.

Modbus Function Codes 

FC

 

01 

through

 06

 and 

16

 are 

supported. Also special Yaskawa Holding Register. 

Each server’s Modbus address must be unique on the 

network!  

All devices on the network must have the same baud rate, up 

to 

500.0kbps

, and the same character framing.

drive.web

 

Training Courses

  

Free

 

online interactive training seminars take about one hour.  

Specialized online and factory training sessions are also 

available.  

To register email 

[email protected] 

or call.

smarty

 

HG503894Beta13

 

 

www.driveweb.com

              

              

Page 

#

/12

12

drive.web

 

40 Log Canoe Circle, Stevensville, MD 21666 USA.  

Ph. 410-604-3400, Fax 410-604-3500, 

www.driveweb.com

Summary of Contents for smarty dw240

Page 1: ...kaging contain recyclable materials This device is designed to comply with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation This Class A digital apparatus is designed to comply with Canadian ICES 003 Cet appa...

Page 2: ...ROCUREMENT OF SUBSTITUTE GOODS OR SERVICES LOSS OF USE DATA OR PROFITS OR BUSINESS INTERRUPTION HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY WHETHER IN CONTRACT STRICT LIABILITY OR TORT INCLUDING NEGLIGENCE OR OTHERWISE ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE Product Identification smarty Cassette Models smarty is a programmable device ...

Page 3: ...coder input 5 5VDC max 0 5VDC min 0 3VDC minimum differential Voltage Up to 1MHz ModbusRTU serial port is brought out to terminals instead of the jack in C2 smarty C4 Carrier 4 Ratings and Features adds to C3 Two 4 20mA current inputs Also 0 20mA 20 4mA and 20 0mA 100Ω input impedance Maximum input is 25mA 2 5VDC Six frequency event digital inputs 30Vmax 100kHz Replaces FT on C3 Seven frequency st...

Page 4: ...n and blinks for activity 100BaseTX Green LED when 100BaseTX connection is made Carriers C1 and C2 Terminals and Dimensions smarty HG503894Beta13 www driveweb com Page 12 4 use in order only ctual size hite beyond 02441 for ol Gray 99 00mm Ref ue Drawing Title Drawn by Property of smarty front label art Ian Bardwell Jones Bardac Corp drive web smarty 100 1 2 PoE lOlOl r use in order only actual si...

Page 5: ...V A B Carrier C3 Terminals and Dimensions Realtime Clock Battery CR2032 Realtime clock will be maintained for approximately 24hrs with no backup battery 4P4C XIO Port 8P8C CANopen Serial Port Width Overall 140mm 5 51 Height Overall 87mm 3 43 DINrail release clip Overall Height Back Panel to Front Panel 75mm 2 95 DI Digital Input DO Digital Output AO Analog Output AI Analog Input 1A Encoder 1 Chann...

Page 6: ...5 TO7 0V 0V 0V 0V 0V 0V 0V 24V 0V 24V 0V A B 0V 1A 1A 1B 1B 0V 2A 2A 2B 2B Carrier C4 Terminals and Dimensions 4P4C XIO Port 8P8C CANopen Serial Port Width Overall 210mm 8 27 Height Overall 87mm 3 43 DI Digital Input DO Digital Output AO Analog Output AI Analog Input CI Current Input 1A Encoder 1 Channel A 1B Encoder 1 Channel B 1Z Encoder 1 Marker 5V 5VDC Power Output FI Frequency Input TPW Power...

Page 7: ...o the unit depending on the installation Signal Wiring Notes Use twisted pair wiring for encoder and serial differential signals Outside metal enclosure use shielded cable with individually shielded twisted pairs such as Belden 8163 Ground shield at one end with a 360 ground clamp where cable enters quiet metal enclosure Separate wiring from AC power cables or RF noise sources smarty I O Functions...

Page 8: ...s for each drive web device and the host computer For systems with more than one drive web device use an Ethernet switch for all drive web devices and computer Get started with savvy We strongly recommend attending our free online training seminars See page 12 We strongly recommend you read the User Manual and Getting Started Guides under the Help menu Use Create Phantom in the Directory menu to e...

Page 9: ... Import Export Device Data Load save configuration data to from this smarty only Unlock Lock Set Password Choose Restrict Modification to allow viewing the configuration or Restrict All Access Click the smarty icon to view the device configuration Function Block Engine Window FBE Menu Standard savvy no SFD Add function blocks in the order to be processed Processing order is left to right top to bo...

Page 10: ...n blocks and connections is at the left of the Signal Flow Diagram showing program execution order from top down Change execution order by dragging function blocks up or down the list In this picture ENC1 Speed function block is moved so that it is processed after ENC Phase Lock savvyPanel Operator Station Computers Apple mobile digital devices iPad iPhone and iPod Touch are operator touch station...

Page 11: ... in Java based savvyPanel Appears as graphic tile in iOS Function blocks enable savvyPanel actions Alarm Annunciator Provides a system wide alarm annunciation when active Touch to view page 255 Presence Monitor Indicates the presence of a tagged savvyPanel application viewing a particular page Latch and SR Latch For lighted start stop pushbuttons Setpoint Monitor Adjust meter and setter range Dual...

Page 12: ...t write or force parameters that are read only or have incoming drive web connections Click the Comms Server icon in the FBE or SFD view dwOption 04 ModbusTCP IP slave server Supported Modbus Function Codes 1 thru 6 15 and 16 Supports up to five simultaneous clients masters dwOption 25 EIP PCCC Server Supports PLC5 Typed Write and Typed Read commands See Appendix B of the savvy User Manual for inf...

Reviews: