background image

drive.web automation

smarty

 

HG503894Beta13

 

 

www.driveweb.com

              

              

Page 

#

/12

5

0V

DI1

DI3

DI5

DI7

DO1

DO3

DO5

DO7

0V

A01

AO3

AO5

AO7

AI1

AI3

AI5

AI7

0V

0V

1A+

1B+

0V

0V

FT1

FT3

24V

DI2

DI4

DI6

DI8

DO2

DO4

DO6

DO8

0V

A02

AO4

AO6

AO8

AI2

AI4

AI6

AI8

0V

5V

1A-

1B-

0V

5V

FT2

FT4

0V

0V

0V

0V

0V

24V

0V

A

B

Carrier C3 

Terminals 

and Dimensions

Realtime Clock Battery, 
CR2032.
(Realtime clock will be 
maintained for 
approximately 24hrs 
with no backup battery.)

4P4C XIO Port

8P8C CANopen 
Serial Port

W

id

th

 O

ve
ra

ll, 

1

4

0

mm 

(5

.5

1

”)

H

e

ig

h

t O

ve
ra

ll,

 

8

7

mm 

(3

.4

3

”)

+ -

DINrail release clip

Overall Height; Back 

Panel to Front Panel 
75mm (2.95”)

DI = Digital Input
DO = Digital Output
AO = Analog Output
AI = Analog Input
1A = Encoder 1 Channel A
1B = Encoder 1 Channel B
5V = 5VDC Power Output 
FT = Frequency/Timing IO
A, B = ModbusRTU

Summary of Contents for smarty dw240

Page 1: ...kaging contain recyclable materials This device is designed to comply with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation This Class A digital apparatus is designed to comply with Canadian ICES 003 Cet appa...

Page 2: ...ROCUREMENT OF SUBSTITUTE GOODS OR SERVICES LOSS OF USE DATA OR PROFITS OR BUSINESS INTERRUPTION HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY WHETHER IN CONTRACT STRICT LIABILITY OR TORT INCLUDING NEGLIGENCE OR OTHERWISE ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE Product Identification smarty Cassette Models smarty is a programmable device ...

Page 3: ...coder input 5 5VDC max 0 5VDC min 0 3VDC minimum differential Voltage Up to 1MHz ModbusRTU serial port is brought out to terminals instead of the jack in C2 smarty C4 Carrier 4 Ratings and Features adds to C3 Two 4 20mA current inputs Also 0 20mA 20 4mA and 20 0mA 100Ω input impedance Maximum input is 25mA 2 5VDC Six frequency event digital inputs 30Vmax 100kHz Replaces FT on C3 Seven frequency st...

Page 4: ...n and blinks for activity 100BaseTX Green LED when 100BaseTX connection is made Carriers C1 and C2 Terminals and Dimensions smarty HG503894Beta13 www driveweb com Page 12 4 use in order only ctual size hite beyond 02441 for ol Gray 99 00mm Ref ue Drawing Title Drawn by Property of smarty front label art Ian Bardwell Jones Bardac Corp drive web smarty 100 1 2 PoE lOlOl r use in order only actual si...

Page 5: ...V A B Carrier C3 Terminals and Dimensions Realtime Clock Battery CR2032 Realtime clock will be maintained for approximately 24hrs with no backup battery 4P4C XIO Port 8P8C CANopen Serial Port Width Overall 140mm 5 51 Height Overall 87mm 3 43 DINrail release clip Overall Height Back Panel to Front Panel 75mm 2 95 DI Digital Input DO Digital Output AO Analog Output AI Analog Input 1A Encoder 1 Chann...

Page 6: ...5 TO7 0V 0V 0V 0V 0V 0V 0V 24V 0V 24V 0V A B 0V 1A 1A 1B 1B 0V 2A 2A 2B 2B Carrier C4 Terminals and Dimensions 4P4C XIO Port 8P8C CANopen Serial Port Width Overall 210mm 8 27 Height Overall 87mm 3 43 DI Digital Input DO Digital Output AO Analog Output AI Analog Input CI Current Input 1A Encoder 1 Channel A 1B Encoder 1 Channel B 1Z Encoder 1 Marker 5V 5VDC Power Output FI Frequency Input TPW Power...

Page 7: ...o the unit depending on the installation Signal Wiring Notes Use twisted pair wiring for encoder and serial differential signals Outside metal enclosure use shielded cable with individually shielded twisted pairs such as Belden 8163 Ground shield at one end with a 360 ground clamp where cable enters quiet metal enclosure Separate wiring from AC power cables or RF noise sources smarty I O Functions...

Page 8: ...s for each drive web device and the host computer For systems with more than one drive web device use an Ethernet switch for all drive web devices and computer Get started with savvy We strongly recommend attending our free online training seminars See page 12 We strongly recommend you read the User Manual and Getting Started Guides under the Help menu Use Create Phantom in the Directory menu to e...

Page 9: ... Import Export Device Data Load save configuration data to from this smarty only Unlock Lock Set Password Choose Restrict Modification to allow viewing the configuration or Restrict All Access Click the smarty icon to view the device configuration Function Block Engine Window FBE Menu Standard savvy no SFD Add function blocks in the order to be processed Processing order is left to right top to bo...

Page 10: ...n blocks and connections is at the left of the Signal Flow Diagram showing program execution order from top down Change execution order by dragging function blocks up or down the list In this picture ENC1 Speed function block is moved so that it is processed after ENC Phase Lock savvyPanel Operator Station Computers Apple mobile digital devices iPad iPhone and iPod Touch are operator touch station...

Page 11: ... in Java based savvyPanel Appears as graphic tile in iOS Function blocks enable savvyPanel actions Alarm Annunciator Provides a system wide alarm annunciation when active Touch to view page 255 Presence Monitor Indicates the presence of a tagged savvyPanel application viewing a particular page Latch and SR Latch For lighted start stop pushbuttons Setpoint Monitor Adjust meter and setter range Dual...

Page 12: ...t write or force parameters that are read only or have incoming drive web connections Click the Comms Server icon in the FBE or SFD view dwOption 04 ModbusTCP IP slave server Supported Modbus Function Codes 1 thru 6 15 and 16 Supports up to five simultaneous clients masters dwOption 25 EIP PCCC Server Supports PLC5 Typed Write and Typed Read commands See Appendix B of the savvy User Manual for inf...

Reviews: