TORQUE VALUES FOR STANDARD ENGLISH FASTENERS
Chart 2
Nominal Thread Diameter
[inch]
Standard Torque
±±
10%
[Nm]
1/4
10
5/16
21
3/8
38
7/16
60
1/2
92
9/16
130
5/8
180
3/4
325
7/8
520
1
780
1- 1/8
1110
1- 1/4
1565
1- 3/8
2050
1- 1/2
2720
1- 3/4
3380
2
5080
6.12. TORQUE VALUES FOR SPLIT FLANGE CONNECTIONS
The following chart 3 provides the tightening torques for split flange connections used in hydraulic
systems. Split flanges and fitting shoulders should fit squarely. Install all bolts, finger tighten and
then torque evenly. Overtorquing bolts will damage the flanges and/or bolts, which may cause
leakage.
Chart 3
Bolt size in inches
Flange size in inches*
Torque Value Nm
1/2
5/16
20
÷
24
3/4
3/8
30
÷
37
1
3/8
37
÷
47
1-1/4
7/16
47
÷
61
1- 1/2
1/ 2
62
÷
79
2
1/ 2
75
÷
88
2- 1/2
1/ 2
107
÷
123
3
5/8
187
÷
203
3- 1/2
5/8
159
÷
180
*
)
Outside diameter of hydraulic tube or hose fitting.
Summary of Contents for 560C
Page 1: ...OM560C99 1E OPERATOR S MANUAL 560C SERIAL NUMBERS 15001 AND UP ...
Page 3: ......
Page 5: ......
Page 7: ......
Page 10: ...SECTION 1 INTRODUCTION ...
Page 12: ......
Page 16: ...SECTION 2 SAFETY PRECAUTIONS ...
Page 18: ......
Page 32: ...SECTION 3 MACHINE TRANSPORT AND STORAGE ...
Page 34: ......
Page 42: ...SECTION 4 OPERATING ...
Page 43: ......
Page 45: ......
Page 49: ...SECTION 4 OPERATING Page 6 OM560C99 1E DRESSTA UNIVERSAL SYMBOLS FOR INSTRUMENTS AND CONTROLS ...
Page 88: ...SECTION 5 MAINTENANCE ...
Page 141: ...SECTION 6 SPECIFICATIONS ...
Page 143: ......