Technical Data
20
UL
(Underwriters Laboratories Inc.)
P3S
Only as to Intrinsic Safety for use in Hazardous Locations
Class I, Div. 1, Groups A, B, C, D
Class II, Div. 1, Groups E, F, G
Use in accordance with Dräger Control Drawing SE20105.
T4: –40
≤
Ta
≤
+65
o
C, T6: –40
≤
Ta
≤
+40
o
C.
Not tested in oxygen enriched atmospheres (>21 % O
2
).
Power Supply: V
max
= 30 V, I
max
= 0.3 A, P
i
= 700 mW,
C
i
= 0 nF, L
i
= 50 µH
Meter circuit: V
oc
= 7.6 V, I
sc
= 1 mA, V
max
= 10.4 V, C
a
= 2.5 µF, L
a
= 10 mH,
C
i
= 0, L
i
= 0
CSA
(Canadian Standards Associa-
tion)
P3S
Intrinsic safe
Class I, Div. 1, Groups A, B, C, D
Class II, Div. 1, Groups E, F, G
Use in accordance with Dräger Control Drawing SE20106.
Power supply: V
max
= 30 V, I
max
= 0.3 A, P
max
= 700 mW,
C
i
= 5 nF, L
i
= 50 µH
Signal transmission to central unit
Analogue
— Measured-value signal
4 mA to 20 mA
— Drift below zero point
3.8 mA to 4 mA
— Full-scale value exceeded
20 mA to 20.5 mA
— Unit fault
<3.2 mA
— Maintenance signal
3.4 mA ±0.2 mA constant
Power supply
Power supply
12 V DC to 30 V DC
Protection against polarity reversal.
Terminals for 0.5 to 2.5 mm
2
(20 to 14 AWG).
Physical specifications
Cable inlet
M20x1.5, for cable diameter 6 to 12 mm (0.24" to 0.47")
Dimensions (H x W x D)
166 mm x 135 mm x 129 mm (6.54" x 5.31" x 5.08)
Weight
approx. 0.9 kg / 2.0 lbs.
Ambient conditions
Specifications for the sensor: see sensor data sheet
for operation
–40 to 65
o
C (–40 to 160
o
F)
1)
700 to 1300 hPa (20.7 to 38.4 inch Hg)
0 to 100 % relative humidity, non condensing
1)
The legibility of the display is restricted at temperatures below –20
o
C (–5
o
F).
during storage
–40 to 70
o
C (–40 to 150
o
F)
700 to 1300 hPa (20.7 to 38.4 inch Hg)
0 to 100 % relative humidity, non condensing
NRTL/C
®
LR97594
Summary of Contents for Polytron 3000
Page 25: ...25 ATEX approval ATEX approval ...
Page 26: ...ATEX approval 26 ...
Page 27: ...27 ATEX approval ...
Page 28: ...ATEX approval 28 ...
Page 29: ...29 ATEX approval ...
Page 30: ...ATEX approval 30 ...
Page 31: ...31 ATEX approval ...
Page 32: ...ATEX approval 32 ...
Page 33: ...33 ATEX approval ...
Page 34: ...ATEX approval 34 ...
Page 35: ...35 ATEX approval ...
Page 36: ...ATEX approval 36 ...
Page 37: ...37 ATEX approval ...
Page 38: ...ATEX approval 38 ...
Page 39: ...39 ATEX approval ...
Page 40: ...ATEX approval 40 ...
Page 41: ...41 ATEX approval ...
Page 42: ...ATEX approval 42 ...
Page 43: ...43 ATEX approval ...
Page 44: ...ATEX approval 44 ...
Page 45: ...45 ATEX approval ...
Page 46: ...ATEX approval 46 ...
Page 47: ...47 IECEx approval IECEx approval ...
Page 48: ...IECEx approval 48 ...
Page 49: ...49 IECEx approval ...
Page 50: ...IECEx approval 50 ...
Page 51: ...51 UL approval UL approval ...
Page 52: ...UL approval 52 ...
Page 62: ...Declaration of Conformity 62 Declaration of Conformity ...
Page 63: ...63 Declaration of Conformity ...
Page 64: ...64 ...
Page 65: ...65 Drilling templates Dräger docking station 66 4 mm 02723758_1 eps ...
Page 66: ......
Page 67: ......