Technical data
Dräger CPS 7900
35
10.3 Resistance to permeation by chemicals
in accordance with BS EN 8467:2006
For the approval, tests were performed at a concentration of
100g/m² over a period of 240 minutes.
D-mex
blue
D-mex
orange
Seams
Visor
Test chemicals
Permeation in
μ
g/cm²
Mustard gas (HD)
<0.1
<0.1
<0.1
0.2
Sarin (GB)
<0.1
<0.1
<0.1
<0.1
Soman (GD)
<0.1
<0.1
<0.1
<0.1
VX <0.1
<0.1
<0.1
<0.1
Zipper mechanism
Safety boots
(Nitril-P)
Glove
combination 2
Glove
combination 3
Test chemicals
Permeation in
μ
g/cm²
Mustard gas (HD)
0.1
<0.1
<0.1
<0.1
Sarin (GB)
0.2
<0.1
<0.1
<0.1
Soman (GD)
0.1
<0.1
<0.1
0.1
VX <0.1
<0.1
<0.1
<0.1