Page10
4.
4.
Error Message and Troubleshooting
The Meaning of Log Field
SW>ERR = System water intake error
A.
B.
C.
D.
1.
Please go to control menu and press “SW Tube De-Gas” and also check if the Sodium Bicarbonate
pump is functioning.
Please check all sections of tank water intake tube and make sure they are free of blockage.
Please gently open the “Reaction Chamber” and make sure the white water level sensor is freely
movable up and down.
Sensor may be malfunctioned. Please contact your dealer.
eg: 10/07 15:07:49 W.131 %0 AK.35.00 KH :7.90
•
•
•
•
•
10/07 22:12
Date / Time.
W.131
Tank Water Input Pump run how many pitches.
%0
optically matching agent dropped speed to assess the percentage of possible errors.
AK.35.00
calculated automatically supplemented 22.15 cc baking soda.
KH :7.90
KH value 7.90 dKH (not before adding baking soda).