background image

 

Err Range (dKH) :

This is to set the variance range in comparison to the previous dKH value. If the difference of this test 
deviates a preset error range from the last known dKH value, the KHG will setup second testing immediately 
to verify the result. The unit of value is dKH. We recommend to set it at 0.5 dKH.
 

Err Try :

This is to set the number of retest to be taken, if the Err Range condition were met.
 

Last KH (dKH) :

This is only used after a system reset or diagnostics, or if instructed by a qualified KHG support staff.

ADJ KH (dKH) :

This is to force adjustment (correction) of the value obtained by KHG. This is normally used if you believe 
there is a constant deviation between the value tested by KHG versus another test kit, and you believe 
KHG's value need to be adjusted every time. You can enter the deviation in here. The adjustment value can 
be either positive or negative.
 

Enable KH Auto :

Enter “1” to activate automatic mode. Any other number will cancel the automatic mode. (Feature not 
available fo M model.)
 

KH auto correction :

This is to set your desired tank dKH value. The unit is dKH. As a full functioning dKH controller, KHG not 
only monitors your tank alkalinity, but with KH auto correction, KHG will also actively maintain your desired 
dKH level. Regardless if you normally maintain your tank alkalinity by kalkwasser, calcium reactor, or 
alkalinity dosing, we highly recommend you set your usual alkalinity dosing to a level slightly below your 

desired target, and let KHG do the final fine tuning for your tank automatically. (Feature not available fo M 

model.)

For example. If your desired tank dKH is 7.5, then please set this number at this field. At the same time, 

please setup your normal alkalinity dosing to near 7.0, and let KHG do the rest. KHG will calculate the 
difference of the actual tank alkalinity level versus the desired target. Taking account of the total tank 
volume, KHG will calculate how much sodium bicarbonate solution to add after each testing.

M.L.Q :

MLQ sets the maximum amount of sodium bicarbonate that KHG can add at any given time. Unit is milliliter 
(ml). This is the safety feature for your tank to prevent too much alkalinity to be added into the tank at any 
given time. (Feature not available fo M model.)

For example, if this time KHG determines 80 ml should be added into your tank, but you have set the MLQ 
at 35 ml, then KHG will only add 35 ml this time into the tank.

Page 8

4.

5.

6.

7.

8.

9.

10.

User Manual

Summary of Contents for KHG

Page 1: ...WWW KHGUARDIAN CO M V8 0C Profashional Edition 2017 01 09...

Page 2: ......

Page 3: ......

Page 4: ...ction Main Display KHG System Setup The Meaning of Log Field Error Message and Troubleshooting Additional User Instructions The KHG exterior features Main Control of KHG P1 P5 P1 P5 P7 P10 P10 P12 P1...

Page 5: ...bicarbonate solution should be added to the aquarium with the reference of the desired dKH target value aquarium total water volume and current testing value Then the controller dose in the solution...

Page 6: ...e sure the placement of KHG is level on the X Y and Z axis Complete levelling is crucial as to keep the sodium bicarbonate solution from dripping on the optical and electronical components before ente...

Page 7: ...eagent solution bottle Please insert the pH probe into pH 7 0 calibration solution of at least 1 5 cm deep Press and hold number 2 and number 4 buttons simultaneously for 3 second until you hear a bee...

Page 8: ...many times as out of the inlet tube Please click on the KS De Gas on your browser to purge air from your KHG reagent solution tube Please look into the observation hole Figure 6 until you see reagent...

Page 9: ...t be performed every time you intend to move the KHG It is crucial to purge reaction chamber to prevent solutions damaging the optical lens and other electronic components Failure to purge chamber cou...

Page 10: ...not use unless being instructed by a qualified KHG support staff ENG Mode OFF Advanced function only Do not use unless being instructed by a qualified KHG support staff Test KH doser Press to test if...

Page 11: ...between each KHG test Unit is minutes We recommend setting the intervals to 180 minutes You can shorten the testing interval time but that will also use up KH reagent solution faster No_SW_ERR This is...

Page 12: ...ntroller KHG not only monitors your tank alkalinity but with KH auto correction KHG will also actively maintain your desired dKH level Regardless if you normally maintain your tank alkalinity by kalkw...

Page 13: ...Save all settings above to the memory KHG will force reboot after new settings have been saved New PW Please enter new password Password allows maximum 8 characters include spaces numbers letters or...

Page 14: ...e Please gently open the Reaction Chamber and make sure the white water level sensor is freely movable up and down Sensor may be malfunctioned Please contact your dealer eg 10 07 15 07 49 W 131 0 AK 3...

Page 15: ...ensor may be malfunctioned Please contact your dealer KH ERR KH value high error A B C D E F 4 This error message indicates the tested value is 1 5dKH larger than the KH auto correction setting System...

Page 16: ...bration procedure If all settings are correct please contact your dealer Page12 4 Additional User Instructions 1 2 3 Upon initial assembly and installation please make sure to perform 5 five dKH readi...

Page 17: ...the factory supplied KHG reagents However the lack of preservatives may result in black color bacteria substances growing in the tubing From the test result of using KHG in the last 4 years these sub...

Page 18: ...mixing 65 grams of sodium bicarbonate powder per one liter of water Please keep the error tolerance to within 5 We would strongly recommend to keep KHG in a protected container away from saltwater sp...

Page 19: ...Press and hold buttons 2 4 for 3 seconds To KS_DS_Gas Press and hold buttons 1 2 for 3 seconds To SW_Tube De_Gas Press and hold buttons 1 3 for 3 seconds To Purge Chamber Press and hold buttons 3 4 fo...

Page 20: ...Contact SALES KHGUARDIAN COM SUPPORT KHGUARDIAN COM...

Reviews: