background image

USER MANUAL

NetGuardian 224A

May 30, 2017

Visit our website at www.dpstelecom.com for the latest PDF manual and FAQs.

D-PK-NG224-12003

D-UM-NG224

Summary of Contents for D-PK-NG224-12003

Page 1: ...USER MANUAL NetGuardian 224A May 30 2017 Visit our website at www dpstelecom com for the latest PDFmanual and FAQs D PK NG224 12003 D UM NG224...

Page 2: ...ance or use of this manual Notice Revision History May 30 2017 March 23 2017 October 24 2016 July 19 2016 April 27 2015 March 10 2015 December 23 2014 November 18 2014 November 22 2013 November 13 201...

Page 3: ...ms 6 3 12 Quick Start How to Connect to the NetGuardian 224A 7 14 via Craft Port using TTY Interface 7 1 14 via LAN 7 2 20 TTY Interface 8 21 Configure Serial Port via TTY 8 1 22 Quick Turn Up 9 22 Ho...

Page 4: ...4 54 Ping Targets 11 5 55 System Alarms 11 6 56 Graph 11 7 57 Device Access Descriptions 12 58 Backup Configuration 13 59 Firmware Upgrade 14 60 Reference Section 15 61 Display Mapping 15 1 61 System...

Page 5: ...Outputs Fast integrated and secure Web browser 32 ping targets to monitor other devices on the network Meet the NetGuardian 224A This small device keeps tabs on all the environmental levels that affec...

Page 6: ...port connection In addition to its 24 discrete input points the NetGuardian 224A has 2 control relays both form C for user defined NO NC connections 2 analogs and dwire The control relays allow netwo...

Page 7: ...0 Firefox Chrome Protocols HTTPS DCPx TELNET HTTP Email SNMP Support V1 V2c V3 1 D Wire SensorSupport Temp Temp Humidity Temp Airflow Ping Alarms 32 Note 1 Valid if hardware option is included 2 Minim...

Page 8: ...DPS Telecom at 1 800 622 3314 NetGuardian 224A D PK NG224 NetGuardian 224AResource CD NetGuardian 224AUser Manual D UM NGDIN 6 ft USB Download Cable D PR 046 10A 06 x 2 x 2 3 4 Amp GMT Fuses 2 741 00...

Page 9: ...5...

Page 10: ...6 x 8 x 4 3 8 Ear Screws 1 000 60375 05 Metric Rack Screws 2 000 80750 03 x 4 Two Standard Rack Screws 1 000 12500 06 Pads 2 015 00030 00...

Page 11: ...7 Optional Shipping Items Available by Request 3 1 Small WAGO connector 2 802 01020 00...

Page 12: ...erminal Mounting 4 2 The NetGuardian 224A can be flush or rear mounted The NetGuardian 224A mounts in a 19 rack or a 23 rack using the provided rack ears for each size Two rack ear locations are provi...

Page 13: ...return into the power connector plug s right terminal and tighten the screw 5 Insert a battery lead to the plug s left terminal and tighten its screw 6 Insert fuse into the fuse distribution panel 7...

Page 14: ...es not have power USB Flashing Green Data Transmitted over USB Flashing Red Data Received over USB D Wire Solid Green At least 1 dwire enabled no alarm Flashing Green Standing acknowledged alarm Thres...

Page 15: ...ggable See next section for wiring For alarms 1 24 the inputs are TTL 5V biased Pluggable Connectors 6 2 If your controls use a pluggable connector attach your wires into the included screw down 6 pin...

Page 16: ...12 66Block diagrams 6 3 66 block pinout for Amphenol 1 TTL Discretes 1 24...

Page 17: ...13 66 block pinout for Amphenol 2 Controls 1 2...

Page 18: ...using TTY Interface 7 1 NetGuardian 224A Craft Port Use the front panel craft port to connect the NetGuardian 224A IT to a PC for onsite unit configuration To use the craft port connect the included...

Page 19: ...15 2 Select Install from a list or specific location Advanced 3 Click Next 4 Select Search for the best driver in these locations 5 Insert NetGuardian 224A Resource Disc CD into your PC 6 Click Browse...

Page 20: ...ssage will confirm installation of a new USB Communications Port 8 Click Finish to close the Wizard Now that the driver has been installed a new COM port is being emulated on your PC Before using hype...

Page 21: ...17 9 Right click the My Computer icon on your desktop then click Manage 10 Click Device Manager in the left pane...

Page 22: ...k on the Start menu select Programs Accessories Communications HyperTerminal 13 At the Connection Description screen enter a name for this connection You may also select an icon The name and icon do n...

Page 23: ...Com port you are using on your PC and make sure you are using the cable provided Additional cables can be ordered from DPS Telecom 17 The NetGuardian 224A s main menu will appear Type C for C onfig th...

Page 24: ...p your PC s current IP address and subnet mask and write this information down 3 Reset your PC s IP address to 192 168 1 200 Contact your IT department if you are unsure how to do this 4 Reset your PC...

Page 25: ...Telnet sessions are established at port 2002 not the standard Telnet port as an added security measure If you re using Windows 7 then you ll need to install telnet before you can use the TTY interface...

Page 26: ...Port Type 232 485 Baud 9600 57600 19200 9600 4800 2400 1200 Parity None even odd Stop bits 1 2 3 Set the RTS head tail Carrier time Suggested settings are 0 0 if using RS232 Quick Turn Up 9 The next...

Page 27: ...ication Setting screen use the drop down box to set what events to use for this notification Now select the Send Email Notification button and click Save and Next 3 At the Email Notification screen yo...

Page 28: ...test the email notification you ve just setup you will prompted with a pop up Click OK to send a test email alarm notification Confirm all your settings by checking your email to see if you ve receiv...

Page 29: ...sure we ve made our default dps_public 2 Click on the Notifications button in the Provisioning menu You can setup as many as 8 different notifications Begin the setup wizard by clicking Edit for a not...

Page 30: ...different hours on the weekend Use the check boxes to select the days of the week and select the time from the drop down menus Click Save and Finish To try a test notification click the Test button S...

Page 31: ...locally The web interface will then prompt you to either Write your changes to the unit or Reboot the unit for changes to take effect in the top left corner of your browser The relevant options will b...

Page 32: ...or use with T Mon DCP Unit ID User definable ID number for the target unit DCP Address DCP Unit Protocol Drop down menu of available protocols for use with DCP Address DCP over LAN port Enter the DCP...

Page 33: ...g of all alarm events in either plain text event log open with notepad or spreadsheet format eventlog csv open with Excel Bypass Login File can be downloaded without logging in when checked Purge Log...

Page 34: ...31607 9 28E5644407000046 test 75 750 75 750 75 750 F 2011 02 03 11 12 27 1296731547 9 28E5644407000046 test 75 750 75 750 75 750 F 2011 02 03 11 11 27 1296731487 9 28E5644407000046 test 75 750 75 750...

Page 35: ...me Enter a username or a user description Password Enter a unique user password Note All passwords are AES 128 encrypted Confirm Password Re enter the password Access Rights Check all Enables all Acce...

Page 36: ...e or backed up configuration files Get audit log Allows the user to access the Audit Log Get Log command Purge delete audit logAllows the user to deletes the existing audit log Get backup config Backs...

Page 37: ...r DHCP server The IP you ve already assigned to the unit becomes inactive Using DHCP means the unit will NOT operate in a T Mon environment Unit IP IP address of the NetGuardian 224A Subnet Mask A roa...

Page 38: ...Select the appropriate settings from the drop down menu RTS Head Only used if your NetGuardian 224A was built with a 202 modem The most commonly used value is 30 RTS Tail Only used if your NetGuardian...

Page 39: ...P SET requests Read and Write Access This field defines how the NetGuardian 224A unit may be accessed via SNMP This can be set to the following Access Disabled Restricts all access to unit via SNMP SN...

Page 40: ...feature has been tested with Gmail To send with Gmail SMTP server do the following SMTP Server IP or Host Name should be set to smtp gmail com Port number must be set to 465 SMTP authentication radio...

Page 41: ...NMP Trap Server IP The SNMP trap manager s IP address Trap Port No The SNMP port UDP port set by the SNMP trap manager to receive traps usually set to 162 Trap Community Community name for SNMP TRAP r...

Page 42: ...schedules for each The Schedule creation screen Notification Scheduling Days of the week From either Schedule 1 or 2 check which days you want to receive notifications Any Time Select this is if you w...

Page 43: ...closure is an alarm When polarity is reversed a normally closed alarm point is clear when closed Notification Devices Check which notification device s 1 through 8 you want to send alarm notifications...

Page 44: ...The Provisioning Controls screen Basic Controls Configuration ID ID number for the control relay Description User definable description for the NetGuardian 224A s control relay Momentary Time Control...

Page 45: ...ications for this analog input Details Record Freq The frequency with which the NetGuardian will record the analog reading Deadband The additional qualifying value the NetGuardian requires above below...

Page 46: ...onfigure D Wire sensors select notification devices and set thresholds The Provisioning Sensors menu Basic Sensor Configuration ID Sensor ID number ROM ID The ID number found on the sticker of the tem...

Page 47: ...ithout interruption in order for the condition to be considered an Alarm or a Clear Qual Type Qualification Type Allows you to choose whether you want to apply the Qualification Time to the alarm Set...

Page 48: ...t MjU to 20 Set MnU to 10 Set MnO to a small value Once the air flow gets to that value the HVAC will be considered starting Set MjO to a higher value This value will be the minimum amount of airflow...

Page 49: ...tracking A Script Sensor is configured to evaluate Reverse Polish Notation equations A data token in an equation can represent a discrete alarm analog reading sensor reading relay status system alarm...

Page 50: ...h value a5 a8 a6 Push value a6 a5 a8 Add a5 a6 a8 Pop a6 and a5 add them push result to stack Multiply a8 a5 a6 Pop a5 a6 and a8 multiply them push result to stack a4 Push value a4 a8 a5 a6 Subtract a...

Page 51: ...ng Targets menu Provisioning Ping Targets ID ID number for the ping target Enab Check this box to enable the ping target Description User definable description for the ping target Server IP or Hostnam...

Page 52: ...stem Alarms menu Editing System Alarms Pnt Point The system alarm point number Description Non editable description for this System housekeeping Alarm Silence Check this box to choose to silence this...

Page 53: ...49 Timers 10 13 Enter the amount of time in seconds sec or minutes m in each value field and click Save The Provisioning Timers menu...

Page 54: ...dress or host name then click Sync Example us pool ntp org Note Make sure to configure DNS before using host name instead of IP address Time Zone Select your time zone from the drop down menu Adjust C...

Page 55: ...us will appear in red if an alarm has been activated The status will be displayed in green when the alarm condition is not present Click on Alarms in the Monitor menu to see if any base alarms 1 8 hav...

Page 56: ...and operate control relays from the Monitor Controls menu Control Relay Operation ID ID number for the control relay Description Description for the NetGuardian 224A s control relay defined in the Pr...

Page 57: ...tion of each analog channel the current reading the units being read and alarm conditions major under minor under major over minor over according to your temperature settings If configured under Provi...

Page 58: ...for minor alarms or red for major alarms Fig 12 5 Current status of all analog inputs in the Monitor User Analogs in Table View Fig 12 6 Current status of all analog inputs in the Monitor User Analog...

Page 59: ...5 Ping Targets can be viewed by going to Monitor Ping Targets Here you can view the state either Clear or Alarm for each of your configured Ping Targets View the status of Ping Targets from the Monito...

Page 60: ...stem alarms by indicating if an alarm has been triggered Under the State column the status will appear in red if an alarm has been activated The status will be displayed in green when the alarm condit...

Page 61: ...n Average Min Max and Start End Times Once you have entered all of the desired values click Build Graph Provision the Channels Group Interval Group Function and more all from the Graph Parameters sect...

Page 62: ...ottom left of the web interface Device Access Option Description Backup Config Backs up the units configuration settings Read Reads a configuration file from the unit Write Commits all changes made in...

Page 63: ...ser download the file to your desktop or other location on your computer 3 Now your configuration should be saved If you need to upload a configuration follow the steps below To upload your configurat...

Page 64: ...he bottom of this screen click the Restore Configuration link located in the System Controls section To upload firmware click on Upload on the top right corner of the web interface At the Firmware Loa...

Page 65: ...99 1 41 48 NTP failed 99 1 49 Timed Tick 99 1 50 Serial 1 RcvQ full 99 1 51 Dynamic memory full 99 1 52 Unit reset 99 1 53 DCP poller inactive 99 1 54 Reserved 99 1 55 64 Display 2 Ping Alarms 1 32 99...

Page 66: ...tal Sensor 2 Major Under 99 1 35 Digital Sensor 2 Major Over 99 1 36 Digital Sensor 2 Not detected 99 1 37 Digital Sensor 2 HVAC Fail 99 1 38 Digital Sensor 2 Air Flow Below Normal 99 1 39 Digital Sen...

Page 67: ...4 Digital Sensor 7 Not Detected 99 1 5 Digital Sensor 7 HVAC Fail 99 1 6 Digital Sensor 7 Air Flow Below Normal 99 1 7 Digital Sensor 7 Mate not detected 99 1 8 Control 99 1 9 16 Value 99 1 17 32 Digi...

Page 68: ...64 Digital Sensor 10 HVAC Fail 99 1 38 Digital Sensor 10 Air Flow Below Normal 99 1 39 Digital Sensor 10 Mate not detected 99 1 40 Control 99 1 41 48 Value 99 1 49 64 Display Mapping...

Page 69: ...4 Digital Sensor 13 Not Detected 99 1 5 Digital Sensor 13 HVAC Fail 99 1 6 Digital Sensor 13 Air Flow Below Normal 99 1 7 Digital Sensor 13 Mate not detected 99 1 8 Control 99 1 9 16 Value 99 1 17 32...

Page 70: ...nfiguration 35 MAC Address Not Set 36 IP Address Not Set 37 LAN hardware error 38 SNMP Process Error 39 SNMP Community Error 40 LAN TX packet drop 41 Notification 1 Failed 42 Notification 2 Failed 43...

Page 71: ...B1 O _OV_Traps points _OV_vTraps 1 3 6 1 4 1 2682 1 2 0 PointSet 20 PointClr 21 SumPSet 101 SumPClr 102 ComFailed 103 ComRestored 014 P0001Set 10001 through P0064Set 10064 P0001Clr 20001 through P006...

Page 72: ...ription 0 Version Public Request Trap Request 1 3 6 1 4 1 2682 1 4 Enterprise 126 10 230 181 Agent address Enterprise Specific Generic Trap 8001 Specific Trap 617077 Time stamp 1 3 7 1 2 1 1 1 0 Objec...

Page 73: ...e subnet mask and the default gateway A sample configuration could look like this Unit Address 192 168 1 100 subnet mask 255 255 255 0 Default Gateway 192 168 1 1 Save your changes by writing to NVRAM...

Page 74: ...r all DPS Telecom products Q How many traps are triggered when a single point is set or cleared The MIB defines traps like major alarm set cleared RTU point set and a lot of granular traps which could...

Page 75: ...rmation when you call our Technical Support representatives can assist you in gathering it Please write the information down for easy access Please have your user manual and hardware serial number rea...

Page 76: ...old it harmless for and against any and all claims damages losses costs expenses obligations liabilities fees and costs and all amounts paid in settlement of any claim action or suit which may be asse...

Page 77: ...73...

Page 78: ......

Page 79: ...lightning unless and to the extent that the product specification provides for resistance to a defined disaster e damage caused by unauthorized attachments or modifications f damage during shipment fr...

Page 80: ...ct manuals Product datasheets Exclusive user forms Expert tips on using your alarm monitoring equipment advanced techniques that will save you hours of work Educational White Papers deliver fast infor...

Reviews: